Multicenter Study Clinical TrialLessons learned from data logging in a multicenter clinical trial using a late-generation implantable cardioverter-defibrillator. The Guardian ATP 4210 Multicenter Investigators Group.
- M A Wood, B S Stambler, R J Damiano, P Greenway, and K A Ellenbogen.
- Medical College of Virginia, Richmond 23298.
- J. Am. Coll. Cardiol. 1994 Dec 1; 24 (7): 1692-9.
ObjectivesThis study examined patterns of implantable cardioverter-defibrillator use as documented by data logging.BackgroundImplantable cardioverter-defibrillators are accepted therapy for malignant ventricular tachyarrhythmias; however, relatively little is known about their patterns of use. Incorporation of data-storage capacities into these devices provides insight into long-term defibrillator function.MethodsStored data-logging information was retrieved from 401 implanted cardioverter-defibrillators in 393 patients over an average of 303 days of follow-up.ResultsA total of 91,443 detections were recorded in 299 patients. One hundred-six patients (26%) had detections due to supraventricular tachycardias, electrical noise or other causes, resulting in inappropriate therapy delivery to 92 patients (23%). Two hundred eighty-one patients recorded 66,276 episodes of ventricular tachycardia or ventricular fibrillation. Of these, 74.4% episodes terminated spontaneously without any delivered therapy, 22.1% terminated after antitachycardia pacing, and 1.7% terminated after shock therapy. Antitachycardia pacing was activated without formal testing in 47% of all patients receiving this therapy and was successful in 96% of all episodes receiving this therapy. Acceleration of tachycardia to shock therapy occurred in 1.3% of all episodes and in 30.5% of patients receiving antitachycardia pacing. Thirty-four patients (8.7%) died during follow-up. Mortality was associated with patient age, heart failure functional class at implantation and frequency of shocks received during follow-up (all p < or = 0.05).ConclusionsMost ventricular tachyarrhythmia detections by this noncommitted implantable cardioverter-defibrillator resolve spontaneously, whereas the majority receiving therapy can be treated with antitachycardia pacing. Mortality after implantable cardioverter-defibrillator implantation is associated with age, heart failure class and frequency of shocks received during follow-up. Data-logging capabilities provide valuable insights into the patterns of defibrillator use.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.