• Nihon Kyobu Shikkan Gakkai Zasshi · Oct 1997

    [Usefulness and early detection of acute exacerbation by peak expiratory flow rate in the management of asthma].

    • Y Iwasaki, Y Kubota, I Yokomura, M Ueda, S Hashimoto, K Mizobuchi, T Arimoto, H Hara, and M Nakagawa.
    • Second Department of Medicine, Kyoto Prefectural University of Medicine, Japan.
    • Nihon Kyobu Shikkan Gakkai Zasshi. 1997 Oct 1; 35 (10): 1040-6.

    AbstractThe monitoring of peak expiratory flow (PEF) and maintenance of a symptom diary have been proposed as means to monitor asthma severity. This study assessed via longitudinal analysis, the usefulness and limitation of daily PEF monitoring (amplitude percent mean) as an index for asthma severity, and the usefulness of recording daily intake of beta-agonists as a measure of symptom severity. Nine subjects with moderate to severe asthma were treated with inhaled beclomethasone dipropionate (BDP). Sustained-release theophylline and oral corticosteroids supplemented inhaled BDP according to both individual symptom prevalence and PEF measurements. The patients kept records four times daily of their PEF and asthmatic symptoms (cough, sputum and number of attacks), from the beginning to the end of treatment. They also recorded the daily frequency of beta-agonist inhalation (as needed for symptomatic relief). Minimum daily PEF (expressed as percent best) correlated significantly with symptom scores: cough (r = -0.69), sputum (r = -0.69) and attack (r = -0.69). Minimum PEF correlated strongly with the daily frequency of beta agonist inhalation (r = 0.76). Each symptom score and the daily frequency of beta-agonist inhalation was zero when the minimum PEF was approximately 80%. We evaluated the correlation between minimum PEF and daily PEF variability in all data (r = -0.72): for a minimum PEF > or = 20% (r = -0.72), a minimum PEF > or = 30% (r = -0.77), a minimum PEF > or = 40% (r = -0.82) and a minimum PEF > or = 50% (r = -0.80). We determined the correlation between minimum PEFs of > or = 35 to 45% in 1% increments and daily PEF variability in relation to the severity of asthma. With a minimum PEF > or = 40%, the strongest correlation was demonstrated between minimum PEF and daily PEF variability. Daily PEF variability was a reliable indicator for the management of asthma when the PEF > or = 40%. When the minimum PEF was 80%, daily PEF variability was approximately 10%. When the minimum PEF was 40%, daily PEF variability was 46%, and the daily frequency of beta-agonist inhalation was 2.6. We concluded that, 1) The target values of minimum PEF and daily PEF variability are 80% and 10% respectively in the treatment of asthmatic patients, 2) The daily frequency of beta-agonist inhalation is recommended as an indicator for the severity of asthmatic symptoms, and 3) Daily PEF variability in combination with the daily frequency of beta-agonist inhalation is very useful in the management and early detection of acute asthma.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.