• Kyobu Geka · Nov 2018

    [Clinical Experience of Aortic Valve Replacement Using the New Stentless Bioprosthesis].

    • Tetsuro Uchida, Azumi Hamasaki, Yoshinori Kuroda, Ken Nakamura, Masahiro Mizumoto, Atsushi Yamashita, Jun Hayashi, Shuto Hirooka, Ai Ishizawa, Kentaro Akabane, and Mitsuaki Sadahiro.
    • Second Department of Surgery, Yamagata University Faculty of Medicine, Yamagata, Japan.
    • Kyobu Geka. 2018 Nov 1; 71 (12): 983-988.

    BackgroundThe SOLO SMART valve is a bovine pericardial stentless bioprosthesis which shows superior hemodynamic performance compared to the stented valves. It is designed for supraannular and subcoronary implantation. We report our surgical experience and results in patients undergoing aortic valve replacement(AVR) with this new bioprosthesis.MethodsSince June 2016, 19 patients with various types of aortic valve disease (mean age:72±7 years, 58% males) have undergone AVR with a SOLO SMART stentless bioprosthesis. Fourteen patients(74%)showed aortic stenosis( AS) and 9 patients(47%)had concomitant procedures;coronary bypass grafting (n=4), mitral valve surgery (n=3), total arch replacement (n=1), and pulmonary venous isolation( n=1). There was 1 patient with active infective valve endocarditis( IE) complicated with annular abscess and 1 patient was a redo AVR case. Surgical results of these patients were evaluated retrospectively. The hemodynamic performance was investigated with transthoracic echocardiography in pre and postoperative period.ResultsThere was no operative death and 1 hospital death (postoperative subdural hematoma;Heyde syndrome). One patient showed a mild trans-prosthetic valve leak. No patient required reoperation. Although postoperative transient thrombocytopenia was noted, it had cured at the time of discharge. At the last echocardiographic evaluation, the peak and mean gradients in the patients undergoing AVR for AS were 17±7 and 9±5 mmHg, respectively. No prosthesis-patient mismatch (PPM) occurred in any patient.ConclusionsAVR using a SOLO SMART stentless bioprosthesis was performed with acceptable morbidity and mortality. The SOLO SMART stentless bioprosthesis showed excellent hemodynamic performance and early results. Because of favorable effective orifice area, the valve is attractive for patients at risk for PPM. Furthermore, it is expected to contribute to more complex AVR with concomitant mitral valve surgery, active IE or redo situation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…