J. Thorac. Cardiovasc. Surg. · Oct 2014
Finding the ideal biomaterial for aortic valve repair with ex vivo porcine left heart simulator and finite element modeling.
- Hadi Daood Toeg, Ovais Abessi, Talal Al-Atassi, Laurent de Kerchove, Gebrine El-Khoury, Michel Labrosse, and Munir Boodhwani.
- Division of Cardiac Surgery, University of Ottawa Heart Institute, Ottawa, Ontario, Canada.
- J. Thorac. Cardiovasc. Surg.. 2014 Oct 1;148(4):1739-1745.e1.
ObjectivesAortic valve (AV) repair (AVr) has become an attractive alternative to AV replacement for the correction of aortic insufficiency; however, little clinical evidence exists in determining which biomaterial at AVr would be optimal. Cusp replacement in AVr has been associated with increased long-term AVr failure. We measured the hemodynamic and biomaterial properties using an ex vivo porcine AVr model with clinically relevant biomaterials and generated a finite element model to ascertain which materials would be best suited for valve repair.MethodsPorcine aortic roots with intact AVs were placed in a left heart simulator mounted with a high-speed camera for baseline valve assessment. The noncoronary cusp was excised and replaced with autologous porcine pericardium, glutaraldehyde-fixed bovine pericardial patch (Synovis), extracelluar matrix scaffold (CorMatrix), or collagen-impregnated Dacron (Hemashield). The hemodynamic parameters were measured for a range of cardiac outputs (2.5-6.5 L/min) after repair. The biomaterial properties and St Jude Medical pericardial patch were determined using pressurization experiments. Finite element models of the AV and root complex were constructed to determine the hemodynamic characteristics and leaflet stresses.ResultsThe geometric orifice areas after repair were significantly reduced in the Hemashield (P<.05) and CorMatrix (P=.0001) groups. Left ventricular work increased with increasing cardiac output (P=.001) in unrepaired valves, as expected, and was similar among all biomaterial groups. Finite element modeling of the biomaterials displayed differences in the percentage of changes in total Von Mises stress for both replaced (noncoronary cusp) and nonreplaced left and right cusps with the St Jude Medical pericardial patch (+4%, +24%) and autologous porcine pericardium (+5, +26%), with a lower percentage of changes than for the bovine pericardial patch (+12%, +27%), Hemashield (+30%, +9%), and CorMatrix (+13%, +32%).ConclusionsThe present study has shown that postrepair left ventricular work did not increase despite a decrease in geometric orifice areas in the Hemashield and CorMatrix groups. The autologous porcine pericardium and St Jude Medical pericardial patch had the closest profile to normal AVs; therefore, either biomaterial might be best suited. Finally, the increased stresses found in the bovine pericardial patch, Hemashield, and CorMatrix groups might, after prolonged tensile exposure, be associated with late repair failure.Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.