-
J. Am. Coll. Cardiol. · Jun 2010
Randomized Controlled Trial Comparative Study2-year clinical and angiographic outcomes from a randomized trial of polymer-free dual drug-eluting stents versus polymer-based Cypher and Endeavor [corrected] drug-eluting stents.
- Robert A Byrne, Adnan Kastrati, Klaus Tiroch, Stefanie Schulz, Jürgen Pache, Susanne Pinieck, Steffen Massberg, Melchior Seyfarth, Karl-Ludwig Laugwitz, Katrin A Birkmeier, Albert Schömig, Julinda Mehilli, and ISAR-TEST-2 Investigators.
- Deutsches Herzzentrum, Technische Universität, Munich, Germany. byrne@dhm.mhn.de
- J. Am. Coll. Cardiol. 2010 Jun 8; 55 (23): 2536-43.
ObjectivesIn the ISAR-TEST-2 (Intracoronary Stenting and Angiographic Results: Test Efficacy of Three Limus-Eluting Stents) randomized trial, a new-generation sirolimus- and probucol-eluting stent (Dual-DES) demonstrated a 12-month efficacy that was comparable to sirolimus-eluting stents (SES) (Cypher, Cordis Corp., Warren, New Jersey) and superior to zotarolimus-eluting stents (ZES) (Endeavor, Medtronic CardioVascular, Santa Rosa, California). The aim of the current study was to investigate the comparative clinical and angiographic effectiveness of SES, Dual-DES, and ZES between 1 and 2 years.BackgroundLong-term polymer residue is implicated in adverse events associated with delayed vessel healing after drug-eluting stent therapy. The second-generation ZES utilizes an enhanced biocompatibility polymer system whereas a new-generation Dual-DES employs a polymer-free drug-release system.MethodsA total of 1,007 patients undergoing coronary stenting of de novo lesions in native vessels were randomized to treatment with SES (n = 335), Dual-DES (n = 333), or ZES (n = 339). Clinical follow-up was performed to 2 years. Angiographic follow-up was scheduled at 6 to 8 months and 2 years.ResultsThere were no significant differences between groups regarding death/myocardial infarction (SES: 10.2% vs. Dual-DES: 7.8% vs. ZES: 9.2%; p = 0.61) or definite stent thrombosis (SES: 0.9% vs. Dual-DES: 0.9% vs. ZES: 0.6%; p = 0.87). Two-year target lesion revascularization (TLR) was 10.7%, 7.7%, and 14.3% lesions in the SES, Dual-DES, and ZES groups, respectively (p = 0.009). Incident TLR between 1 and 2 years in the Dual-DES group (0.9%) was significantly lower than in the Cypher SES group (3.6%) (p = 0.009), but comparable to the Endeavor ZES group (0.7%) (p = 0.72). These findings mirrored those observed for binary restenosis.ConclusionsAt 2 years, there was no signal of a differential safety profile between the 3 stent platforms. Furthermore, the antirestenotic efficacy of both Dual-DES and ZES remained durable between 1 and 2 years, with Dual-DES maintaining an advantage over the entire 2-year period. (Intracoronary Stenting and Angiographic Results: Test Efficacy of Three Limus-Eluting Stents [ISAR-TEST-2]; NCT00332397).Copyright 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.