• Catheter Cardiovasc Interv · Dec 2011

    Transcatheter aortic valve implantation: lessons from the learning curve of the first 270 high-risk patients.

    • Ronen Gurvitch, Edgar L Tay, Namal Wijesinghe, J Ye, Fabian Nietlispach, David A Wood, Samuel Lichtenstein, Anson Cheung, and John G Webb.
    • Department of Cardiology and Cardiothoracic Surgery, St. Paul's Hospital, University of British Columbia, Vancouver, Canada.
    • Catheter Cardiovasc Interv. 2011 Dec 1; 78 (7): 977-84.

    BackgroundTranscatheter aortic valve implantation (TAVI) is a rapidly evolving strategy for therapy of aortic stenosis. We describe the effect of the learning curve from the first 270 high-risk patients in Vancouver, Canada.MethodsPatients underwent TAVI by transfemoral (63%) or transapical (37%) routes using balloon expandable valves. The experience was divided into the first half (FH, patients 1-135) and second half (SH, patients 136-270).ResultsThe mean age was 83.2 ± 8 years (FH 83 ± 12 vs. SH 81 ± 7 years, P = 0.12). The mean Society of Thoracic Surgeons Score (STS) was 9.5% ± 5.2%- FH 10.5 vs. SH 8.5% (P = 0.01). The overall procedural success rate in the FH was 92.6%, improving to 97.8% in the SH (P = 0.05). The transfemoral procedural success improved-FH 89.3% to SH 98.8% (P = 0.01). The transapical procedural success remained high-FH 98.0% to SH 96.1% (P = 0.53). The overall 30-day mortality was 9.6%, improving from FH 13.3% to SH 5.9% (P = 0.04). In the transfemoral cases, 30-day mortality decreased by 56% [10.7-4.7%, P = 0.14], and similarly in transapical cases [17.6-7.8%, P = 0.14]. In-hospital stroke occurred in 3.3% (FH 3.7% vs. SH 2.9%, P = 0.74). The overall need for a new permanent pacemaker was 5.9% (FH 5.9% vs. SH 5.9%, P = 1). The overall major vascular injury rate was 6.7% (FH 8.1% vs. SH 5.2%, P = 0.33). The overall incidence of coronary vessel occlusion was 1.1% (FH 1.5 % vs. SH 0.7%, P = 0.56). Device embolization or failure to cross the valve was rare and largely seen in the FH only. Procedural experience (>135 procedures) was an independent predictor of 30-day survival (HR: 6.7, 95% CI: 1.2-18.1, P = 0.03).ConclusionTAVI outcomes improve with experience and device development. While overall complication rates are low, scope remains to further reduce procedural adverse events.Copyright © 2011 Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.