• J. Thorac. Cardiovasc. Surg. · Sep 2014

    Observational Study

    Outcomes after implantation of partial-support left ventricular assist devices in inotropic-dependent patients: Do we still need full-support assist devices?

    • Anton Sabashnikov, Aron-Frederik Popov, Christopher T Bowles, Prashant N Mohite, Alexander Weymann, Rachel Hards, Mike Hedger, Thorsten Wittwer, Jens Wippermann, Thorsten Wahlers, Friedrich A Schoendube, and André R Simon.
    • Department of Cardiothoracic Transplantation and Mechanical Circulatory Support, Royal Brompton & Harefield NHS Foundation Trust, Harefield Hospital, Harefield, Middlesex, United Kingdom; Department of Cardiothoracic Surgery, University Hospital of Cologne, Cologne, Germany. Electronic address: a.sabashnikov@rbht.nhs.uk.
    • J. Thorac. Cardiovasc. Surg.. 2014 Sep 1;148(3):1115-21; discussion 1021-2.

    ObjectivesPartial-support left ventricular assist devices (LVADs) represent a novel strategy for heart failure treatment. The Synergy Pocket Micro-pump (HeartWare Inc, Framingham, Mass), the smallest surgically implanted long-term LVAD, provides partial flow up to 4.25 L/min and was primarily designed for "less sick" patients with severe heart failure. This device is implanted minimally invasively without sternotomy or cardiopulmonary bypass. Early implantation in patients with Interagency Registry for Mechanically Assisted Circulatory Support class 4 and higher was shown to be feasible and associated with significantly improved hemodynamics and quality of life. The aim of this study was to present our experience with implementation of long-term partial circulatory support as a bridge to transplantation in patients with more advanced heart failure who were dependent preoperatively on inotropic support or intra-aortic balloon pump.MethodsIn this observational study, only inotropic or intra-aortic balloon pump-dependent patients with end-stage heart failure were included (n = 12). These patients underwent Synergy device implantation between February 2012 and August 2013.ResultsThe mean preoperative Interagency Registry for Mechanically Assisted Circulatory Support class was 2.17 ± 0.84 (class 1, 25%; class 2, 33%; class 3, 42%). The mean age was 46 ± 15 years, and 33% were female. Preoperatively, 4 patients (33%) had at least 1 previous sternotomy, 3 patients (25%) were supported with a balloon pump, 1 patient (8%) had a previous full-support LVAD, and 4 patients (33%) had cerebrovascular events in the past. After device implantation, there were no right ventricular failures, device-related infections, hemorrhagic strokes, arterial or venous thromboembolisms, or worsenings of aortic and mitral regurgitation observed over the follow-up. The mean follow up was 174 ± 171 days (range, 5-764 days; cumulative, 3199 days). One patient (8%) died, 3 patients (25%) successfully underwent transplantation, 1 device (8%) was explanted after myocardial recovery, and 5 patients (42%) are still on ongoing support. Two patients (17%) were upgraded to a full-support LVAD after 65 days of mean support. A total of 11 of 12 patients (92%) were discharged from the hospital and are presently alive. Left ventricular end-diastolic diameter was significantly reduced 3 months after device implantation.ConclusionsPartial LVAD support may be clinically efficacious in inotropic and intra-aortic balloon pump-dependent patients. On the basis of our experience and evidence of previous research, such patients may benefit from minimally invasive access, no need for sternotomy and cardiopulmonary bypass, a short implantation time, an easy exchange if necessary, and a lower risk of subsequent heart transplantation. Because the implantation is performed without sternotomy, device upgrade is feasible with a comparatively low operative risk and good clinical outcome. Our preliminary results show that partial-support devices may have the potential to replace full-support LVADs in the near future.Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.