• J. Thorac. Cardiovasc. Surg. · Jun 1986

    Comparative Study

    An eight-year experience with porcine bioprosthetic cardiac valves.

    • R S Hartz, E B Fisher, B Finkelmeier, A DeBoer, J H Sanders, J M Moran, and L L Michaelis.
    • J. Thorac. Cardiovasc. Surg. 1986 Jun 1; 91 (6): 910-7.

    AbstractA total of 589 porcine bioprostheses were implanted in 509 patients from January, 1976, through December, 1983. Of the valves implanted, 390 were Hancock and 199 were Carpentier-Edwards. A total of 1,633 patient-years was accrued, with a mean follow-up of 38 months per patient. Two hundred eight patients had aortic valve replacement, 209 had mitral valve replacement, and 79 had multiple valve replacements, of which 46 were aortic and mitral replacements. The mortality for isolated aortic valve replacement was 5.8%; for isolated mitral replacement, 8.6%, and for all patients, 10.9%. Late mortality was 3.9% per patient-year. The actuarial survival rate at 5 years was 79% for aortic, 68% for mitral, and 76% for aortic-mitral valve replacement. There were 12 thromboembolic events (0.73% per patient-year). Two episodes occurred in patients with an aortic bioprosthesis, nine in patients with a porcine mitral valve, and one in a patient with mitral and tricuspid bioprosthetic valves. The probability of remaining free of thromboembolism at 5 years was 99% for the group having aortic valve replacement, 93% for those having mitral replacement, and 100% for the group having aortic-mitral valve replacements. Thirteen episodes of endocarditis occurred (0.8% per patient-year). Seven of the 13 patients died as a direct result of endocarditis. The probability of remaining free of prosthetic endocarditis at 5 years was 97% for the aortic valve replacement group, 95% for the mitral group, and 97% for the aortic-mitral group. There were 20 instances of xenograft failure (1.2% per patient-year). The probability of remaining free of valve failure at 5 years was 96% for the aortic valve replacement group, 93% for the mitral group, and 93% for the aortic-mitral replacement group. Primary tissue failure of a prosthesis occurred in seven patients, all with Hancock valves (0.43% per patient-year). As yet there has been no primary tissue failure of the Carpentier-Edwards prosthesis. There also appears to be a lower incidence of thromboembolism (Edwards, 0.3% per patient-year; Hancock, 0.8% per patient-year) and endocarditis (Edwards, 0.6% per patient-year; Hancock, 1.0% per patient-year). The low incidence of complications with the porcine bioprosthetic valve, especially the Carpentier-Edwards, encourages us to recommend its continued use, especially in situations in which anticoagulation is contraindicated.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…