• Bmc Cardiovasc Disor · Feb 2020

    Systematic review on left atrial appendage closure with the LAmbre device in patients with non-valvular atrial fibrillation.

    • Muhammad Ali, Angelos G Rigopoulos, Mammad Mammadov, Abdelrahman Torky, Andrea Auer, Marios Matiakis, Elena Abate, Constantinos Bakogiannis, Stergios Tzikas, Boris Bigalke, Daniel Sedding, and Michel Noutsias.
    • Mid-German Heart Center, Department of Internal Medicine III (KIM-III), Division of Cardiology, Angiology and Intensive Medical Care, University Hospital Halle, Martin-Luther-University Halle, Ernst-Grube-Strasse 40, D-06120, Halle (Saale), Germany.
    • Bmc Cardiovasc Disor. 2020 Feb 12; 20 (1): 78.

    BackgroundPercutaneous closure (LAAC) of the left atrial appendage (LAA) is an efficacious preventive procedure for patients with non-valvular atrial fibrillation (NVAF) and considerable bleeding risk. We sought to systematically review the available LAAC data on the novel occluder device LAmbre™.MethodsFor this systematic review, a search of the literature was conducted by 3 independent reviewers, reporting the safety and therapeutic success of LAAC in patients being treated with a LAmbre™. Publications reporting the safety and therapeutic success of LAAC using LAmbre™ in n > 5 patients were included.ResultsThe literature search retrieved n = 10 publications, encompassing n = 403 NVAF patients treated with a LAmbre™ LAAC, with relevant data regarding safety and therapeutic success of the procedure. The mean CHA2DS2-VASc Score was 4.0 + 0.9, and the mean HAS-BLED score was 3.4 + 0.5. The implantation success was 99.7%, with a mean procedure time of 45.4 ± 18.7 min, and a fluoroscopy time of 9.6 ± 5.9 min, and a contrast agent volume of 96.7 ± 0.7 ml. The anticoagulation regimen was switched to DAPT post procedure in the majority of the patients (96.8%). Partial and full recapture were done in 45.5% and in 25.6%, respectively. Major complications were reported in 2.9%, with 0.3% mortality, 1.7% pericardial tamponade, 0.3% stroke, and 0.6% major bleeding complications; no device embolization was observed. During follow up at 6 or 12 months, major adverse cardiovascular events were reported in 3.3%: Stroke or TIA in 1.7%, thrombus formation on the device in 0.7%, and residual flow > 5 mm in 1.0%. In some publications, the favorable implantion properties of the LAmbre™ for difficult anatomies such as shallow or multilobular LAA anatomies were described.ConclusionsThis systematic review on the LAmbre™ LAA-occluder including n = 403 NVAF patients demonstrates an excellent implantion success rate, promising follow-up clinical data, and favorable properties for also challenging LAA anatomies,. While its design seems to be helpful in preventing device embolization, pericardial tamponade may not be substantially reduced by the LAmbre™ as compared with other established LAAC devices. Further larger prospective multicenter registries and randomized trials are needed to scrutinize the value of the LAmbre™ compared with established LAAC devices.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…