J. Thorac. Cardiovasc. Surg. · Aug 2014
Multicenter Study Observational StudyTranscatheter aortic valve implantation in patients with severe aortic valve stenosis and large aortic annulus, using the self-expanding 31-mm Medtronic CoreValve prosthesis: first clinical experience.
- Freek Nijhoff, Pierfrancesco Agostoni, Hafid Amrane, Azeem Latib, Luca Testa, Jacopo A Oreglia, Federico De Marco, Mariam Samim, Francesco Bedogni, Francesco Maisano, Giuseppe Bruschi, Antonio Colombo, Ad J Van Boven, and Pieter R Stella.
- Department of Cardiology, University Medical Center Utrecht, Utrecht, The Netherlands.
- J. Thorac. Cardiovasc. Surg. 2014 Aug 1; 148 (2): 492-9.e1.
ObjectivesWith the introduction of the 31-mm Medtronic CoreValve prosthesis, patients with large aortic annulus have become eligible for transcatheter aortic valve implantation. The aim of this study was to evaluate the feasibility, efficacy, and safety of transcatheter aortic valve implantation using the 31-mm Medtronic CoreValve in patients with severe aortic valve stenosis and large aortic annulus.MethodsFive institutions in the Netherlands and Italy participated in a retrospective multicenter registry. Clinical, procedural, and imaging data of patients treated with the 31-mm Medtronic CoreValve were retrospectively collected in accordance with the Valve Academic Research Consortium-2 criteria.ResultsBetween August 2011 and November 2012, 47 patients (44 men, mean age 77.6 ± 8.9 years) received the 31-mm Medtronic CoreValve prosthesis for severe aortic stenosis. Device success (correct positioning of a single valve with intended performance and no all-cause 30-day mortality) was achieved in 31 patients (66.0%). Reasons for failing the device success criteria were significant prosthetic aortic regurgitation in 3 patients (6.4%), second valve implantation in 10 patients (21.2%) (8 cases of malpositioning with high-grade aortic regurgitation, 1 acute valve dislocation, and 1 delayed valve dislocation), 1 of whom died intrahospital, and in-hospital mortality in a further 3 patients (6.4%). Peak and mean transaortic gradients decreased significantly (P < .01). The rate of new pacemaker implantations was 41.7%.ConclusionsIn this retrospective multicenter registry, transcatheter treatment of severe aortic valve stenosis with the 31-mm Medtronic CoreValve seemed to be challenging, even in experienced hands. If the prosthesis is properly implanted, it offers adequate valve hemodynamics and proper functioning.Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.