• Respiratory care · Aug 2021

    Effects of Shake-Actuation Delay on Delivered Dose and Aerosol Characteristics of an Albuterol Suspension From a Pressurized Metered-Dose Inhaler.

    • Rasha Qaqish and Ariel Berlinski.
    • Department of Pediatrics, College of Medicine, University of Arkansas for Medical Sciences and Pediatric Aerosol Research Laboratory at Arkansas Children's Research Institute, Little Rock, Arkansas.
    • Respir Care. 2021 Aug 1; 66 (8): 131513221315-1322.

    BackgroundSuspensions delivered via a pressurized metered-dose inhaler (pMDI) require shaking the canister before actuation to prevent drug sedimentation. We hypothesized that a shake-actuation delay of an albuterol hydrofluoroalkane (HFA) pMDI will increase and decrease delivered dose (DOSE) at the beginning and end of the canister's life, respectively, and that aerosol characteristics will remain unchanged with the delay.MethodsAlbuterol HFA pMDIs (90 µg/actuation, 200 doses) operated with and without a 30-s shake-actuation delay, and with and without a valved holding chamber (VHC), were studied. Ten puffs, with a 30-s interval between puffs and 5s of shaking, were actuated into a drug-recovery apparatus. Inhalers were studied throughout their entire life (from 200 doses to 0 remaining doses). Particle size analysis was performed with cascade impaction at the beginning, middle, and end of the canister's life. Albuterol mass was determined via spectrophotometry (276 nm).ResultsMean (99% CI) delivered dose without shake-actuation delay was 100.4% (98.1-102.9%) of the nominal dose. Mean (99% CI) delivered dose with a VHC without a shake-actuation delay was 48.6% (46.2-50.9%) of the nominal dose. The shake-actuation delay increased and decreased delivered dose at the beginning and end of the canister's life, respectively, irrespective of VHC use. Decline in delivered dose began when 110-120 doses remained in the canister. Aerosol characteristics remained constant throughout the canister's life except for the amount of drug captured by the impactor for the pMDI with delay and the pMDI/VHC with delay. Adding a VHC to a pMDI operated with a delay increased fine-particle fraction and decreased the amount of drug captured by the impactor at the middle and at the end of the canister's life.ConclusionsA 30-s shake-actuation delay of an albuterol HFA pMDI increased and decreased delivered dose at the beginning and end of canister's life, respectively. Particle size characteristics at the end of the canister's life changed when the pMDI and pMDI/VHC were operated with a shake-actuation delay. Patients should re-shake the pMDI if it is not actuated immediately after shaking the canister.Copyright © 2021 by Daedalus Enterprises.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.