• Pulm Pharmacol Ther · Oct 2018

    Randomized Controlled Trial

    Effect of a spacer on total systemic and lung bioavailability in healthy volunteers and in vitro performance of the Symbicort® (budesonide/formoterol) pressurized metered dose inhaler.

    • Michael Gillen, Pablo Forte, Jan Olof Svensson, Rosa Lamarca, Joanna Burke, Karolina Rask, Ulrika Larsdotter Nilsson, and Göran Eckerwall.
    • AstraZeneca - Quantitative Clinical Pharmacology, Gaithersburg, USA. Electronic address: michael.gillen@astrazeneca.com.
    • Pulm Pharmacol Ther. 2018 Oct 1; 52: 7-17.

    IntroductionMany patients with chronic obstructive pulmonary disease or asthma experience difficulties in coordinating inhalation with pressurized metered-dose inhaler (pMDI) actuation. The use of a spacer device can improve drug delivery in these patients. The aim of this study was to establish the relative bioavailability of single doses of Symbicort® (budesonide/formoterol) pMDI 160/4.5 μg/actuation (2 actuations) used with and without a spacer device. In addition, an in vitro study was conducted to characterize performance of the inhaler when used in conjunction with a spacer device.MethodsA Phase I, randomized, open-label, single-dose, single-center, crossover study in 50 healthy volunteers (NCT02934607) assessed the relative bioavailability of single-dose Symbicort® pMDI 160/4.5 μg/actuation (2 actuations) with and without a spacer (AeroChamber Plus® Flow-Vu®). Inhaled doses were administered without or with activated charcoal (taken orally) to estimate total systemic exposure and exposure through the lung, respectively. The in vitro study characterized the effect of the spacer with respect to delivered dose, fine particle dose, and dose during simulated breathing of budesonide and formoterol.ResultsIn terms of total systemic exposure, use of the spacer increased the relative bioavailability determined by AUC(0-last) and Cmax by 68% (spacer:no spacer treatment ratio, 167.9%; 90% CI, 144.1 to 195.6) and 99% (ratio, 198.7%; 90% CI, 164.4 to 240.2) for budesonide, and 77% (ratio, 176.6%; 90% CI, 145.1 to 215.0) and 124% (ratio, 223.6%; 90% CI, 189.9 to 263.3) for formoterol, respectively, compared with pMDI alone. Similarly, the lung exposure of budesonide and formoterol increased (AUC(0-last) and Cmax by 146% [ratio, 246.0%; 90% CI, 200.7 to 301.6] and 127% [ratio, 226.5%; 90% CI, 186.4 to 275.4] for budesonide, and 173% [ratio, 272.8%; 90% CI, 202.5 to 367.4] and 136% [ratio, 236.2%; 90% CI, 192.6 to 289.6] for formoterol, respectively) when the pMDI was administered through the spacer. When assessed by AUC(0-last) quartile without spacer, subjects in the lowest exposure quartile (indicating poor inhalation technique) with Symbicort® pMDI 160/4.5 μg/actuation (2 actuations) had markedly increased total systemic and lung exposure when the same dose was administered with the spacer. In contrast, for subjects in the highest exposure quartile with pMDI alone, total systemic and lung exposure of formoterol and budesonide was similar with and without the spacer. In the in vitro study, the fine particle dose (<5 μm) of both budesonide and formoterol from the spacer at delay time (i.e. pause period after actuation) = 0 s (instantaneous) after actuation was similar to the fine particle dose when not using the spacer. The delivered doses of budesonide and formoterol from the spacer were both lower compared with the doses administered without the spacer. There was also a decrease in delivered dose with increasing delay time.ConclusionsThe clinical study demonstrated that in subjects with poor inhalation technique the use of the AeroChamber Plus® Flow-Vu® spacer increased the bioavailability of Symbicort® pMDI to a level observed in subjects with good inhalation technique without a spacer. The findings from the in vitro study support the fine particle dose characteristics of Symbicort® pMDI with the AeroChamber Plus® Flow-Vu® spacer.Copyright © 2018. Published by Elsevier Ltd.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.