-
Journal of cardiology · Oct 2018
Comparative StudySuperiority of novel automated assessment of aortic annulus by intraoperative three-dimensional transesophageal echocardiography in patients with severe aortic stenosis: Comparison with conventional cross-sectional assessment.
- Nahoko Kato, Kentaro Shibayama, Masahiko Noguchi, Yu Makihara, Hiroshi Okumura, Kotaro Obunai, Mitsuaki Isobe, Kenzo Hirao, and Hiroyuki Watanabe.
- Heart Center, Tokyo Bay Urayasu-Ichikawa Medical Center, Urayasu, Japan; Department of Cardiovascular Medicine, Tokyo Medical Dental University, Tokyo, Japan.
- J Cardiol. 2018 Oct 1; 72 (4): 321-327.
BackgroundPrevious studies have demonstrated that three-dimensional (3D) transesophageal echocardiography (TEE) is an alternative to multi-detector computed tomography (MDCT) for aortic valve sizing in transcatheter aortic valve replacement (TAVR). However, conventional cross-sectional analysis of aortic annulus by 3D TEE has some limitations such as lengthy analytical time. A novel software for automated valve measurement has been developed for 3D TEE. We evaluated the accuracy and analytical time of aortic annular measurements using this novel automated software in the clinical setting.MethodsWe retrospectively studied 43 patients with symptomatic severe aortic stenosis (AS) who underwent TAVR. All patients underwent intraoperative TEE and MDCT. We measured aortic annular area by automated, semi-automated, and cross-sectional methods using 3D TEE datasets. These measurements were compared to the corresponding MDCT reference values. We also compared the analytical time of the three methods.ResultsAutomated and semi-automated analyses required significantly shorter analytical time compared to cross-sectional analysis (automated: 30.1±5.79s, semi-automated: 74.1±15.0s, manual: 81.8±18.5s, p<0.05). Compared to MDCT measurement (393.7±81.0mm2), annular areas measured by automated and cross-sectional methods were significantly smaller (automated: 380.6±77.1mm2, cross-sectional: 374.7±76.8mm2, p<0.05), while that obtained by semi-automated method was not significantly different (387.7±75.8mm2). Annular areas determined by semi-automated and cross-sectional analyses had narrower limits of agreement (LOA) with MDCT measurements, compared to automated analysis (automated: -68.6 to 94.7mm2, semi-automated: -48.3 to 60.2mm2, cross-sectional: -40.0 to 77.9mm2). Measurements by all three methods using 3D TEE showed high correlation with MDCT measurement (automated: r=0.86, semi-automated: r=0.94, cross-sectional: r=0.93).ConclusionsFor aortic annular measurements using 3D TEE in AS patients, semi-automated analysis using the novel automated software reduced analytical time while maintaining similar accuracy compared to the conventional cross-sectional analysis. This automated software may have acceptable feasibility in the clinical setting.Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.