• J. Cardiovasc. Electrophysiol. · May 2004

    Comparative Study

    Improvement of defibrillation efficacy with preshock synchronized pacing.

    • Hui-Nam Pak, Yuji Okuyama, Yong-Seog Oh, Hideki Hayashi, Yen-Bin Liu, Peng-Sheng Chen, and Shien-Fong Lin.
    • Division of Cardiology, Department of Medicine, Cedars-Sinai Medical Center and David Geffen School of Medicine, UCLA, 90048, USA.
    • J. Cardiovasc. Electrophysiol. 2004 May 1; 15 (5): 581-7.

    IntroductionWe previously demonstrated that wavefront synchronization by spatiotemporal excitable gap pacing (Sync P) is effective at facilitating spontaneous termination of ventricular fibrillation (VF). Therefore, we hypothesized that a spatiotemporally controlled defibrillation (STCD) strategy using defibrillation shocks preceded by Sync P can improve defibrillation efficacy.Method And ResultsWe explored the STCD effects in 13 isolated rabbit hearts. During VF, a low-voltage gradient (LVG) area was synchronized by Sync P for 0.92 second. For Sync P, optical action potentials (OAPs) adjacent to four pacing electrodes (10 mm apart) were monitored. When one of the electrodes was in the excitable gap, a 5-mA current was administered from all electrodes. A shock was delivered 23 ms after the excitable gap when the LVG area was unexcitable. The effects of STCD was compared to random shocks (C) by evaluating the defibrillation threshold 50% (DFT(50); n = 35 for each) and preshock coupling intervals (n = 208 for STCD, n = 172 for C). Results were as follows. (1) Sync P caused wavefront synchronization as indicated by a decreased number of phase singularity points (P < 0.0001) and reduced spatial dispersion of VF cycle length (P < 0.01). (2) STCD decreased DFT(50) by 10.3% (P < 0.05). (3) The successful shocks showed shorter preshock coupling intervals (CI; P < 0.05) and a higher proportion of unexcitable shock at the LVG area (P < 0.001) than failed shocks. STCD showed shorter CIs (P < 0.05) and a higher unexcitable shock rate at LVG area (P < 0.05) than C.ConclusionSTCD improves defibrillation efficacy by synchronizing VF activations and increasing probability of shock delivery to the unexcitable LVG area.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…