- S Waldhans, S Kasseckert, S Vogt, R Buchert, U F Kroh, and R Moosdorf.
- Klinik für Herzchirurgie, Herzzentrum Marburg.
- Biomed Tech (Berl). 1998 Dec 1; 43 (12): 367-70.
AbstractMimicking the physiological characteristics of the circulatory system, pulsatile bloodflow has also been introduced into extracorporeal perfusion to avoid known postoperative complications. In a mathematical consideration of the situation bloodflow is seen as a function of time F(t) for approximately constant vessel diameter over a given time. The kinetic energy of a column of blood produced by the heart-lung machine is transmitted directly to the arterial circulation via the aorta. The nature of the energy release can give rise to both positive (organ perfusion) and negative (damage to endothelium) effects. This study investigates how this energy release can be optimised, using the following experimental approach. A Doppler flow-measuring probe is placed on the ascending aorta to monitor the extracorporeal circulation. At the same time, the blood pressure is measured and converted to a pressure-flow curve via an A/D converter. On the basis of the parameters thus obtained, the energy released by the heart-lung machine is calculated. By regulating the functional parameters of a new generation of heart-lung machines, the bloodflow can then be adapted to the physiological requirements. Within the pulse period (cycle) a 20% rise phase ending in a slightly increasing plateau is established. The energy increase within a cycle should not exceed 150 joules. To optimize the mode of functioning of the heart-lung machine, we introduced the "energy-equivalent pressure" (EEP). Adaptation of the EEP to the physiological conditions required a basic flow of 60% at a pulse rate of 60/min and a pulse duration of 35% within the pulsatile flow interval.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.