• J. Thorac. Cardiovasc. Surg. · Jan 2014

    Comparative Study Observational Study

    Simple interrupted suturing increases valve performance after aortic valve replacement with a small supra-annular bioprosthesis.

    • Minoru Tabata, Kentaro Shibayama, Hiroyuki Watanabe, Yasunori Sato, Toshihiro Fukui, and Shuichiro Takanashi.
    • Department of Cardiovascular Surgery, Sakakibara Heart Institute, Tokyo, Japan. Electronic address: mtabata@post.harvard.edu.
    • J. Thorac. Cardiovasc. Surg.. 2014 Jan 1;147(1):321-5.

    ObjectiveA supra-annular aortic valve prosthesis is often used for aortic valve replacement in patients with a small aortic annulus. However, which suture technique provides the best valve performance has not been studied. We aimed to compare valve performance between 2 different suture techniques.MethodsWe reviewed 152 patients undergoing aortic valve replacement with a 19- or 21-mm Carpentier-Edwards Perimount Magna aortic bioprosthesis (Edwards Lifesciences, Irvine, Calif) between June 2008 and December 2010. Simple interrupted sutures were used in 102 patients (group A, 19-mm prosthesis in 47 patients and 21-mm prosthesis in 55 patients), and noneverting mattress sutures were used in 50 patients (group B, 19-mm prosthesis in 20 patients and 21-mm prosthesis in 30 patients). Transthoracic echocardiograms were performed at baseline and before discharge in all patients and 1 year after surgery in 141 patients. We compared the effective orifice area and incidence of prosthesis-patient mismatch (effective orifice area index <0.85 cm(2)/m(2)) between 2 groups.ResultsThe mean postoperative effective orifice areas were 1.41 ± 0.32 cm(2)/m(2) in group A and 1.30 ± 0.28 cm(2)/m(2) in group B (P = .025). The incidence of prosthesis-patient mismatch was 29% in group A and 56% in group B (P = .002). A multivariate analysis has shown that simple interrupted suturing is a negative predictor of prosthesis-patient mismatch (odds ratio, 0.33; 95% confidence interval, 0.13-0.83; P = .018). At 1 year, the incidence of prosthesis-patient mismatch was 27% in group A and 47% in group B (P = .023).ConclusionsSimple interrupted sutures provide larger effective orifice areas and reduce the incidence of prosthesis-patient mismatch after aortic valve replacement with a small supra-annular bioprosthesis. This suture technique is preferred in those patients to maximize valve performance.Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.