• Rev Chir Orthop Reparatrice Appar Mot · Jun 2008

    Comparative Study

    [Confrontation of the radiographic preoperative planning with the postoperative data for uncemented total hip arthroplasty].

    • R Debarge, S Lustig, P Neyret, and T Ait Si Selmi.
    • Service de Chirurgie Orthopédique et Traumatologique, Centre Livet, Hôpital de la Croix-Rousse, Caluire, France. r_debarge@hotmail.com
    • Rev Chir Orthop Reparatrice Appar Mot. 2008 Jun 1; 94 (4): 368-75.

    Purpose Of The StudyFor hip prosthesis surgery, the challenge is to obtain optimal function of the instrumented hip but also to eliminate any limb length discrepancy, correct the femur offset and guarantee the center of rotation of the hip joint. Preoperative planning for total hip arthroplasty (THA) enables determination of the appropriate length for the prosthetic neck and the size and eventually the type of implants to use. From a prospective series of 86 patients who underwent first-intention THA for implantation of a noncemented prosthesis, we studied the precision of the outcome as function of the preoperative planning. We also ascertained whether the preoperative planning was sufficient to provide the measurements necessary for correct implant position.Material And MethodsWe analyzed a prospective series of patients who underwent first-intention THA from January 2004 through January 2006. To be eligible for inclusion, patients could not have a THA of the contralateral hip. The series was composed of 58 females and 28 males, mean age 70.2 years (range 45-93). The reasons for THA were primary degenerative disease (n=76) and aseptic osteonecrosis (n=10). The contalateral hip was intact and free of osteoarthritis with an anatomic presentation considered to be normal. The standard X-ray protocol included an anteroposterior view of the pelvis in the upright position and 10 degrees internal rotation obtained preoperatively and three months postoperatively. All radiographic measurements were made by the same investigator using a manual nondigitalized technique. We compared planning parameters (pivot size and type, length of the neck, and size of the cup) with the final outcome in order to determine the compliance with the preoperative planning. All operations were performed in the lateral supine position under general anesthesia and by the same surgeon. The posterolateral Moore approach was used. All implants were press fit without cement, both for the cup and for the femoral piece.ResultsAll planning parameters selected for study (offset, size of the head and the cup, length of the neck) were available for 32 hips, giving an overall conformity of 37%. The length of the neck was as planned in 75% of hips, the size of the cup in 62% and the size of the femoral stem in 64%. The offset defined preoperatively was never changed during the operation. Ideal implantation (+/- 5mm for all criteria selected for study) was obtained in 60% of hips; the height of the center of rotation was reproduced in 81% and the lateralization in 84%. Femur lateralization was reproduced in 75% of the hips and hip offset in 66%. Leg length discrepancy was avoided in 85% of the patients.Discussion And ConclusionPreoperative planning reliably predicts the final offset of the implanted femoral stem. It is more difficult to predict the size of a press fit cup but in our experience the difference does not greatly affect restitution of the hip anatomy. We readily changed the length of the neck during the operation if necessary and have found that the leg length has been better with this approach. This leads to the observation that all of the planning parameters are not fully accurate because of the magnification effect, anatomic conditions, or possible defective execution. While the overall rate of conformity was low, looking at the results for each element separately provided a useful element for each phase of the operation. We recommend planning a medium length neck so it can be easily changed during the operation. The availability of offset measurements is particularly important to control hip lateralization and leg length. Current advances in computer-assisted surgery should be helpful in improving the imperfections of preoperative planning.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…