J. Thorac. Cardiovasc. Surg. · Feb 2013
Postcardiac transplant survival in the current era in patients receiving continuous-flow left ventricular assist devices.
- Forum Kamdar, Ranjit John, Peter Eckman, Monica Colvin-Adams, Sara J Shumway, and Kenneth Liao.
- Division of Cardiology, University of Minnesota Medical Center, Minneapolis, MN, USA.
- J. Thorac. Cardiovasc. Surg.. 2013 Feb 1;145(2):575-81.
ObjectivesContinuous-flow left ventricular assist devices have become the standard of care for patients with heart failure requiring mechanical circulatory support as a bridge to transplant. However, data on long-term post-transplant survival for these patients are limited. We evaluated the effect of continuous-flow left ventricular assist devices on postcardiac transplant survival in the current era.MethodsAll patients who received a continuous-flow left ventricular assist device as a bridge to transplant at a single center from June 2005 to September 2011 were evaluated.ResultsOf the 167 patients who received a continuous-flow left ventricular assist device as a bridge to transplant, 77 (46%) underwent cardiac transplantation, 27 died before transplantation (16%), and 63 (38%) remain listed for transplantation and continued with left ventricular assist device support. The mean age of the transplanted patients was 54.5 ± 11.9 years, 57% had an ischemic etiology, and 20% were women. The overall mean duration of left ventricular assist device support before transplantation was 310 ± 227 days (range, 67-1230 days). The mean duration of left ventricular assist device support did not change in patients who had received a left ventricular assist device in the early period of the study (2005-2008, n = 62) compared with those who had received a left ventricular assist device later (2009-2011, n = 78, 373 vs 392 days, P = NS). In addition, no difference was seen in survival between those patients supported with a left ventricular assist device for fewer than 180 days or longer than 180 days before transplantation (P = NS). The actuarial survival after transplantation at 30 days and 1, 3, and 5 years by Kaplan-Meier analysis was 98.7%, 93.0%, 91.1%, and 88.0%, respectively.ConclusionsThe short- and long-term post-transplant survival for patients bridged with a continuous-flow left ventricular assist device in the current era has been excellent. Furthermore, the duration of left ventricular assist device support did not affect post-transplant survival. The hemodynamic benefits of ventricular unloading with continuous-flow left ventricular assist devices, in addition to their durability and reduced patient morbidity, have contributed to improved post-transplant survival.Copyright © 2013. Published by Mosby, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.