J. Thorac. Cardiovasc. Surg. · Jun 2013
Use of a low-resistance compliant thoracic artificial lung in the pulmonary artery to pulmonary artery configuration.
- Christopher N Scipione, Rebecca E Schewe, Kelly L Koch, Andrew W Shaffer, Amit Iyengar, and Keith E Cook.
- Department of General Surgery, University of Michigan Medical Center, Ann Arbor, Mich, USA.
- J. Thorac. Cardiovasc. Surg. 2013 Jun 1; 145 (6): 1660-6.
BackgroundThoracic artificial lungs have been proposed as a bridge to transplant in patients with end-stage lung disease. Systemic embolic complications can occur after thoracic artificial lung attachment in the pulmonary artery to left atrium configuration. Therefore, we evaluated the function of a compliant thoracic artificial lung attached via the proximal pulmonary artery to distal main pulmonary artery configuration.MethodsThe compliant thoracic artificial lung was attached to 5 sheep (63 ± 0.9 kg) in the proximal pulmonary artery to distal main pulmonary artery configuration. Device function and animal hemodynamics were assessed at baseline and with approximately 60%, 75%, and 90% of cardiac output diverted to the compliant thoracic artificial lung. At each condition, dobutamine (0 and 5 μg·kg(-1)·min(-1)) was used to simulate rest and exercise conditions.ResultsAt rest, cardiac output decreased from 6.20 ± 0.53 L/min at baseline to 5.40 ± 0.43, 4.66 ± 0.31, and 4.05 ± 0.27 L/min with 60%, 75%, and 90% of cardiac output to the compliant thoracic artificial lung, respectively (P < .01 for each flow diversion vs baseline). During exercise, cardiac output decreased from 7.85 ± 0.70 L/min at baseline to 7.46 ± 0.55, 6.93 ± 0.51, and 5.96 ± 0.44 L/min (P = .82, P = .19, and P < .01 with respect to baseline) with 60%, 75%, and 90% of cardiac output to the compliant thoracic artificial lung, respectively. The artificial lung resistance averaged 0.46 ± 0.02 and did not vary significantly with blood flow rate.ConclusionsUse of a compliant thoracic artificial lung may be feasible in the proximal pulmonary artery to distal main pulmonary artery setting if its blood flow is held at less than 75% of cardiac output. To ensure a decrease in cardiac output of less than 10%, a blood flow rate less than 60% of cardiac output is advised.Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.