• Eur J Radiol · Jan 2017

    The evolution of radiation dose over time: Measurement of a patient cohort undergoing whole-body examinations on three computer tomography generations.

    • Roy P Marcus, Elise Koerner, Roland C Aydin, Dominik Zinsser, Tobias Finke, Christian J Cyron, Fabian Bamberg, Konstantin Nikolaou, and Mike Notohamiprodjo.
    • Institute of Diagnostic and Interventional Radiology, Eberhard-Karls-Universität, Tübingen, Germany; Department of Radiology, Mayo Clinic, Rochester, MN, United States. Electronic address: roy.marcus@med.uni-tuebingen.de.
    • Eur J Radiol. 2017 Jan 1; 86: 63-69.

    ObjectivesTo evaluate and compare the radiation dose and image quality of whole-body-CT (WBCT) performed on the 3rd-generation dual-source-CT (DSCT) with 2nd-generation DSCT and 64-slices-Single-Source-CT (SSCT) in a large patient cohort.Material And MethodsUsing a monitoring and tracking software 1451, 747 and 1861 patients scanned with a one-spiral-thorax-abdomen-pelvis-CT-examination on a 3rd-, 2nd-generation DSCT and SSCT, respectively, were extracted from the PACS server. For the intra-individual analysis, 203 patients on the 3rd-generation DSCT were identified. Out of those 203 patients, 155 had the same examination on the 2nd-generation DSCT, 91 patients had the same examination on the SSCT and 43 patients had an examination on all three CT-generations. Automatic tube current modulation was active on all three CT-generations, whereas automatic tube voltage selection was only available on both DSCT-generations. Dose was recorded by the size-specific-dose-estimate-method (SSDE); signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) were calculated placing a ROI on the ascending aorta/liver and the subcutaneous adipose tissue at comparable level. Image quality of axillary and mediastinal lymph nodes and adrenal glands was assessed by two experienced radiologists.ResultsSubjective image quality was excellent throughout all three CT-generations (p=0.38-0.98). Quantitative image quality in both DSCT generations was superior to SSCT (p<0.001). SNR and CNR in the liver parenchyma were superior in the 3rd-generation DSCT compared to the 2nd generation DSCT (p<0.001), whereas there was no difference in the aorta. In the inter-individual analysis, CTDIvol was lower by 26.9% and 44.3% in the 3rd-generation DSCT, when compared to the 2nd-generation DSCT and SSCT, respectively; SSDE was lower by 31.5% and 51% in the 3rd-generation DSCT, when compared to the 2nd-generation DSCT and SSCT, respectively. In the intra-individual comparison CTDIVol in the 3rd-generation DSCT was lower by 33% and 45%, when compared to the 2nd-gneration DSCT and the SSCT, respectively. Consequently, SSDE in the 3rd-generation DSCT was lower by 29% and by 43% when compared to the 2nd-generation DSCT and SSCT, respectively.ConclusionState-of-the-art CT-equipment substantially reduce radiation dose without affecting image quality.Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.