• Eur J Radiol · Feb 2013

    Does positron emission tomography data acquisition impact simultaneous diffusion-weighted imaging in a whole-body PET/MRI system?

    • Christian Buchbender, Verena Hartung-Knemeyer, Philipp Heusch, Till A Heusner, Karsten Beiderwellen, Hans-Joerg Wittsack, Hilmar Kühl, Michael Forsting, Andreas Bockisch, Gerald Antoch, and Rotem S Lanzman.
    • Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, D-40225 Dusseldorf, Germany.
    • Eur J Radiol. 2013 Feb 1; 82 (2): 380-4.

    ObjectivesThe purpose of this study was to test whether the acquisition of positron emission tomography (PET) does interfere with simultaneous diffusion weighted imaging (DWI) in an integrated whole-body PET/MRI system.Material And MethodsFourteen consecutive oncological patients (9 men, 5 women; age 54 ± 13 years ([mean ± standard deviation]) scheduled for routine [(18)F]-FDG PET/CT were prospectively enrolled. For DWI, an echo planar imaging (EPI) sequence (b=0-500-1000 s/mm(2)) was acquired twice on an integrated whole-body 3T PET/MRI system in each patient; first with simultaneous PET acquisition and a second time with the PET component switched off. The apparent diffusion coefficient (ADC) and the signal-to-noise ratio at b=1000 s/mm(2) (SNR) of the myocardium, paraspinal muscle, liver, spleen, renal cortex and tumor tissue (if present) were measured. In addition, the coefficient of variation (CV) of ADC values was calculated. Student's t-test for paired samples was performed to test for differences of the mean ADC, ADC CV and SNR between DWI with and without simultaneous PET acquisition.ResultsThere were no significant differences of the ADC [(mean ± standard deviation)] between the DWI acquisitions with and without simultaneous PET acquisition for the myocardium (2572 ± 441 × 10(-6)mm(2)/s and 2586 ± 376 × 10(-6)mm(2)/s, respectively) (P=0.817), paraspinal muscle (1279 ± 254 × 10(-6)mm(2)/s vs. 1219 ± 181 × 10(-6)mm(2)/s) (P=0.318), liver (1245 ± 158 × 10(-6)mm(2)/s vs. 1254 ± 171 × 10(-6)mm(2)/s) (P=0.848), spleen (980 ± 122 × 10(-6)mm(2)/s vs. 1000 ± 187 × 10(-6)mm(2)/s) (P=0.676) and renal cortex (1951 ± 226 × 10(-6)mm(2)/s vs. 1930 ± 273 × 10(-6)mm(2)/s) (P=0.730). Mean ADC of lymph node metastases (n=6) did not differ between with PET acquisition (853 ± 174 × 10(-6)mm(2)/s) and without simultaneous PET (865 ± 170 × 10(-6)mm(2)/s) (P=0.675). There were no significant differences between the CV of ADC values or the SNR values measured in DWI datasets that were acquired with or without simultaneous PET for any evaluated organ site.ConclusionThe simultaneous acquisition of DWI and PET on an integrated PET/MRI system does not impact ADC quantification of normal and tumor tissue and does not alter SNR. This knowledge provides a basis for the use of simultaneous multiparametric PET/MRI comprising DWI in diagnostic imaging and quantitative tumor therapy monitoring using repeated ADC measurements.Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…