• Investigative radiology · Jun 2008

    Application of automatic vertical positioning software to reduce radiation exposure in multidetector row computed tomography of the chest.

    • Jianhai Li, Unni K Udayasankar, Thomas L Toth, William C Small, and Mannudeep K Kalra.
    • Department of Radiology, Emory University School of Medicine, Atlanta, Georgia 30322, USA.
    • Invest Radiol. 2008 Jun 1; 43 (6): 447-52.

    ObjectiveTo determine the effect of automatic vertical positioning (AVP) software on radiation dose reduction in multidetector row computed tomography of the chest.Materials And MethodsTwo hundred forty-three consecutive patients (mean age, 54; range, 20-93 years), who underwent 64-slice multidetector row computed tomography of the chest from November 2005 to April 2006, were included in this study. This study was approved by our institutional review board with waiver of informed consent. Technologists initially positioned the patient in the gantry by adjusting the table height (vertical positioning) using a laser guidance system and patient surface anatomy. AVP software was then used to determine the true vertical positioning of the patient based on matching the individual patient's mean centroid (center of mass) throughout the chest as determined by the lateral projection with the gantry isocenter and center of the bow-tie filter. The resultant reduction in surface radiation dose with this attenuation-based vertical positioning was then calculated. Software-determined changes in patient vertical positioning and resultant radiation dose savings were analyzed using the t test and Pearson correlation statistics.ResultsVertical positioning of the patients by the technologist differed from AVP with the bow-tie filter in 95.5% (232 of 243) of patients with an average vertical mispositioning distance of 33.2 +/- 1.1 mm (range, 5.1-97 mm). Among mispositioned patients, 97% (225 of 232) were vertically mispositioned below the isocenter with a mean distance of 33.8 +/- 1.1 mm (range, 5.1-97 mm) and 3% (7 of 232) patients were vertically mispositioned above the isocenter, with a mean distance of 12.7 +/- 2.8 mm (range, 6-28 mm). The average surface radiation dose reduction with AVP software was 19% +/- 1% (range, 1%-46.6%). There was a strong correlation between vertical mispositioning distance and the surface radiation dose reduction facilitated by AVP software (r(2) = 0.9, P < 0.001).ConclusionAVP software can help in optimum patient vertical positioning leading to substantial reduction in surface radiation dose.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.