-
- Daniel Z Uslan, Muhammad R Sohail, Jennifer L St Sauver, Paul A Friedman, David L Hayes, Sarah M Stoner, Walter R Wilson, James M Steckelberg, and Larry M Baddour.
- Department of Medicine, Division of Infectious Diseases, Mayo Clinic College of Medicine, 200 First Street SW, Rochester, MN 55905, USA. duslan@mednet.ucla.edu
- Arch Intern Med. 2007 Apr 9; 167 (7): 669-75.
BackgroundThe incidence of cardiac device infection is not well understood. Bloodstream infection (BSI) in patients with permanent pacemakers or implantable cardioverter-defibrillators (hereafter, defibrillators) may reflect device infection.MethodsRetrospective, population-based cohort study of all adult patients with cardiac devices who resided in Olmsted County, Minnesota, from 1975 to 2004. The medical linkage-system of the Rochester Epidemiology Project and standardized criteria were used to identify all cases of BSI and device infection. The incidence of device infection was calculated with person-years of follow-up after device implantation.ResultsA total of 1524 patients with cardiac devices were included in the cohort. Total person-time of follow-up was 7578 years. The incidence of definite device infection was 1.9 per 1000 device-years (95% confidence interval [CI], 1.1-3.1). The incidence of pocket infection without BSI was 1.37 per 1000 device-years (95% CI, 0.62-3.05), and pocket infection with BSI or device-related endocarditis 1.14 per 1000 device years (95% CI, 0.47-2.74). The cumulative probability of device infection was higher among patients with defibrillators compared with those with pacemakers, P<.001. Twelve (54.6%) of 22 cases of Staphylococcus aureus BSI had definite or possible cardiac device infection vs 3 (12.0%) of 25 cases of bloodstream infection due to gram-negative bacilli (P = .004).ConclusionsTo our knowledge, this is the first population-based study to describe the incidence of cardiac device infection. Device infection was common during episodes of S aureus BSI. The rate of cardiac device infection was higher in patients with defibrillators than in those with pacemakers.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.