• J. Thorac. Cardiovasc. Surg. · May 2013

    Multicenter Study

    Four-dimensional, flow-sensitive magnetic resonance imaging of blood flow patterns in thoracic aortic dissections.

    • Christopher J François, Michael Markl, Mark L Schiebler, Eric Niespodzany, Benjamin R Landgraf, Christian Schlensak, and Alex Frydrychowicz.
    • Department of Radiology, University of Wisconsin-Madison, Madison, WI 53562, USA. cfrancois@uwhealth.org
    • J. Thorac. Cardiovasc. Surg.. 2013 May 1;145(5):1359-66.

    ObjectiveThe purpose of this study was to evaluate alterations in flow patterns in thoracic aortic dissections using 4-dimensional, flow-sensitive magnetic resonance imaging.MethodsThis prospective study was conducted at 2 academic tertiary referral medical centers. Thirteen 4-dimensional flow magnetic resonance imaging studies were performed in 12 subjects (4 female, aged 25-71 years) with thoracic aortic dissection using 3.0T clinical scanners. Qualitative assessment of flow patterns in the true and false lumina was performed in consensus by 3 cardiovascular radiologists. Quantitative analysis included measurement of net flow, retrograde flow, peak flow, and time-to-peak flow in the true and false lumina in the ascending aorta, aortic arch, and descending aorta. Differences in flow through the true and false lumina at each analysis plane were compared with the 2-tailed, paired Student t test.ResultsFlow patterns were significantly altered in association with different extents of disease, vessel dilatation, and post-therapeutic anatomy. Total flow per cardiac cycle and peak flow were higher in the true lumen than in the false lumen (P < .01). Retrograde flow was less in the true lumen than in the false lumen (P ≤ .01). Time-to-peak flow in the true lumen occurred later than in the false lumen (P = .05-.08).ConclusionsFour-dimensional, flow-sensitive magnetic resonance imaging at 3.0T provided qualitative and quantitative information on alterations of aortic flow in patients with thoracic aortic dissection. Future application of this magnetic resonance flow methodology may help provide insights into the pathophysiology and effects of flow alterations and establish prognostic indicators for the development of complications or aneurysm growth in patients with aortic dissection.Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…