J Magn Reson Imaging · Sep 2008
Multicenter StudyEvaluation of cardiac biventricular segmentation from multiaxis MRI data: a multicenter study.
- Jyrki M P Lötjönen, Vesa M Järvinen, Benjamin Cheong, Edwin Wu, Sari Kivistö, Juha R Koikkalainen, Jussi J O Mattila, Helena M Kervinen, Raja Muthupillai, Florence H Sheehan, and Kirsi Lauerma.
- VTT Technical Research Centre of Finland, Tampere, Finland. jyrki.lotjonen@vtt.fi
- J Magn Reson Imaging. 2008 Sep 1; 28 (3): 626-36.
PurposeTo validate a volumetric biventricular segmentation solution for multiaxis cardiac magnetic resonance (CMR) images.Materials And MethodsThe study population comprised 40 subjects. Biventricular end-diastolic and -systolic phases were segmented from both short-axis and horizontal long-axis or transaxial cine CMR images. Segmentation was based on fitting nonrigidly a 3D surface model to multiaxis CMR images. Five segmentations were performed: two manual segmentations by experts, automatic segmentation, and two segmentations where a user was allowed to correct errors in the automatic segmentation for 2 minutes and without time limits. Volumetry, distance measures, and visual grading were used to evaluate the quality of the segmentation.ResultsNo difference was observed between automatic and manual segmentations in volumetric measures of the ventricles. The manual segmentation performed better for left-ventricular myocardial volume. The distance between surfaces as well as visual analysis did not show differences between automatic and manual segmentation for the endocardial border of the left ventricle but some corrections are needed for the right ventricle.ConclusionFully automatic segmentation produces good results in the assessment of left ventricular volume andendocardial border. Two minutes of user interaction are needed to obtain accurate results for the right ventricle.Copyright (c) 2008 Wiley-Liss, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.