-
Neurological research · Jun 2018
225 intracranial aneurysms treated with the Low-profile Visualized Intraluminal Support (LVIS) stent: a single-center retrospective study.
- Wei Su, Yisen Zhang, Junfan Chen, Jian Liu, Gary Rajah, and Xinjian Yang.
- a Beijing Neurosurgical Institute, Beijing Tiantan Hospital , Capital Medical University , Beijing , China.
- Neurol. Res. 2018 Jun 1; 40 (6): 445-451.
AbstractBackground For the treatment of intracranial aneurysms, the low-profile visualized intraluminal support (LVIS) stent is a new generation of highly visible-braided stent that was recently introduced in China. Here, we report our single-center retrospective experience of safety and efficacy utilizing LVIS for stent-assisted coiling of intracranial aneurysms. Methods We included 218 patients with intracranial aneurysms consecutively treated with LVIS SR stents at our center in this study. Postoperative and follow-up embolization scores, procedural complications, clinical and angiographic findings at mid-term follow-up, as well as recurrence rate, preoperative and follow-up mRS scores were analyzed. Results Two hundred and eighteen patients with two hundred and twenty five intracranial aneurysms were enrolled. The locations and distribution were ICA (125, 55.6%), PcomA (47, 20.9%), VA (38, 16.8%), and BA (15, 6.7%). Two hundred and eighteen aneurysms were treated with the stent-assisted coiling and seven patients with LVIS stents alone. Angiographic follow-up was available for 115 (51.1%) aneurysms, 8 (7.0%) of which had recurrences including 7 (6.5%) unruptured aneurysms and 1(14.3%) ruptured aneurysm. The procedural complication rate was 2.75% in total, including distal hemorrhage (1, 0.45%; SAH), ischemic events (5, 2.3%). Conclusions Our single-center retrospective experience is one of the larger studies to date assessing the LVIS device. Compared with many laser-cut stent studies, the LVIS device had a higher aneurysm complete occlusion rate at follow-up coupled with low complication rates. However, this study was our initial experience with LVIS, larger patient numbers, and longer follow-up will be needed to fully assess the long-term efficacy of LVIS in treating intracranial aneurysms.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.