    PurposeInsertion of a laryngeal mask airway (LMA) is occasionally difficult in children because of their anatomical features and variations. A new single-use supraglottic airway device, the i-gel airway, was recently introduced. The objective of this study was to show the initial experience of the i-gel airway device by the residents for pediatric patients.MethodsWith approval from the local ethics committee and parental informed consent, 70 children undergoing minor surgery in the supine position, ASA score I-II, were investigated. Exclusion included patients having thoracic, neurosurgical, spine, and otolaryngological procedures. Patients were divided into three groups: group 1 was airway size 1.5 for patients weighing 5-12 kg, group 2 was size 2 for 10-25 kg, and group 3 was size 2.5 for those weighing 25-35 kg. The following seven characteristics were evaluated: (1) ease of the i-gel and gastric tube insertion; (2) leak pressure; (3) tidal volume/body weight at leak pressure point; (4) fiberscope score; (5) insertion time; (6) hypoxia rate (laryngospasm); and (7) coughing and trace of bleeding.ResultsThe overall insertion success rate and the success rate at first attempt were 99% and 94%, respectively. Gastric tube insertions were easy in all patients. The overall leak pressure was 23 ± 5 cmH(2)O. The tidal volume per body weight was 24 ± 10 ml/kg. A good view of the fiberscope was achieved in 79%. In group 1 (size 1.5), one failed insertion, two dislocations, and one dysphonia were observed. Hypoxia rate was 1%. There was no case with coughing and trace of bleeding.ConclusionThese results show that the i-gel airway is a safe and effective device for use by residents who do not have experience with insertion of a pediatric LMA. However, using size 1.5, special caution should be taken to protect the infant airway, similar to what has been previously reported for other airway devices.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,704,841 articles already indexed!

We guarantee your privacy. Your email address will not be shared.