    Impact of iodine delivery rate with varying flow rates on image quality in dual-energy CT of patients with suspected pulmonary embolism.

    • Jan Hansmann, Christian Fink, Gregor Jost, Hubertus Pietsch, Mathias Meyer, John W Nance, Uwe J Schoepf, Ulrike I Attenberger, Stefan O Schoenberg, and Thomas Henzler.
    • Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim - Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim, Germany.
    • Acad Radiol. 2013 Aug 1; 20 (8): 962-71.

    Rationale And ObjectivesTo prospectively compare four contrast material injection protocols for dual-energy computed tomography (CT) pulmonary angiography (DE-CTPA) in patients with suspected pulmonary embolism (PE).Materials And MethodsOne hundred twenty consecutive patients were randomized to contrast material injection protocols defined by different iodine concentrations and iodine delivery rates (IDRs): (A) 80 mL iopromide 370/4 mL/sec = IDR 1.4 gI/sec; (B) 80 mL iopromide 370 at 3 mL/sec = IDR 1.1 gI/sec; (C) 98 mL iopromide 300 at 4.9 mL/sec = IDR 1.4 gI/sec; and (D) 98 mL iopromide 300 at 3.7 mL/sec = IDR 1.1 gI/sec. Attenuation values were measured in the inflow tract (subclavian vein-superior vena cava-right atrium), target tract (right ventricle-pulmonary trunk-pulmonary arteries), and outflow tract (left atrium-left ventricle-ascending aorta). Two readers assessed subjective image quality of CTPA images and iodine perfusion maps. The number of artifacts due to hyperdense contrast material on iodine perfusion maps was recorded.ResultsTarget tract attenuation was highest for protocol A with 374 ± 98 Hounsfield units (HU) (highly concentrated contrast material/high IDR). This was significant compared to protocols B and D (P = .0118, P = .0427) but not compared to protocol C (P = .3395). No significant difference in target tract attenuation was found between protocols B (309 ± 80 HU), protocol C (352 ± 119 HU), and D (325 ± 74 HU). CTPA and iodine perfusion map image quality for protocol A was rated significantly higher compared to all other protocols (median score = 5/4; P < .0001 for both) with moderate interreader agreement (κ = 0.58/0.47). Protocols A and B displayed increased artifacts on iodine perfusion maps compared to protocols C and D (3 versus 2).ConclusionDespite increased artifacts on iodine perfusion maps, highly concentrated iodinated contrast material combined with high flow rates provides improved diagnostic image quality and has the highest target-tract attenuation for DE-CTPA protocols.Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.