Comparative Study
Assessment of liver fibrosis with gadoxetic acid-enhanced MRI: comparisons with transient elastography, ElastPQ, and serologic fibrosis markers.
- Hyeon Ji Jang, Ji Hye Min, Jeong Eun Lee, Kyung Sook Shin, Kyung-Hee Kim, and Seo-Youn Choi.
- Department of Radiology, Chungnam National University Hospital, Chungnam National University College of Medicine, Daejeon, Republic of Korea.
- Abdom Radiol (NY). 2019 Aug 1; 44 (8): 2769-2780.
ObjectivesTo compare the diagnostic performance of gadoxetic acid-enhanced magnetic resonance imaging (MRI), ultrasonography (US)-based elastography, and serologic fibrosis markers in assessing the stage of liver fibrosis.Materials And MethodsThis retrospective study included 67 patients (55 male and 12 female; mean age 62.5 years) who underwent gadoxetic acid-enhanced MRI and liver stiffness measurements before liver biopsy or surgery between January 2014 and January 2018. Measurements were performed using transient elastography (TE), ultrasound shear wave elastography point quantification (ElastPQ), and blood tests. The following MRI-based fibrosis markers were assessed: contrast enhancement index (CEI), liver-spleen contrast ratio (LSC), liver-portal vein contrast ratio (LPC), and signal intensity ratio (SIR). The diagnostic performances of fibrosis markers were compared using the area under the receiver operating characteristic curve (AUC), with histopathologic fibrosis stage as the reference standard.ResultsThe fibrosis stages were F0-F1 (n = 17), F2 (n = 7), F3 (n = 20), and F4 (n = 23). MRI-based fibrosis markers negatively correlated with histologic stage: CEI (r = -0.786); LSC (r = - 0.718); LPC (r = - 0.448); and SIR (r = - 0.617; all P < 0.001). For diagnosis of either significant liver fibrosis (≥ F2) or cirrhosis (F4), the CEI provided better diagnostic accuracy (AUC = 0.898 and 0.881) than the aspartate aminotransferase-to-platelet ratio index (APRI) (AUC = 0.699 and 0.715; all P < 0.05). The CEI displayed similar diagnostic accuracy for ≥ F2 or F4 when using TE (AUC = 0.866 and 0.884, both P > 0.05) or ElastPQ [AUC = 0.751 (P = 0.021) and AUC = 0.786 (P = 0.234)].ConclusionsThe CEI measured by gadoxetic acid-enhanced MRI allows the staging of liver fibrosis, with a diagnostic accuracy comparable to that of TE and superior to that of ElastPQ or APRI.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.