Eur. J. Obstet. Gynecol. Reprod. Biol. · Dec 2016
Comparative StudyV-Loc™ 180 suture in total laparoscopic hysterectomy: a retrospective study comparing Polysorb to barbed suture used for vaginal cuff closure.
- Lin Cong, Congqing Li, Bing Wei, Lei Zhan, Wenyan Wang, and Youjiang Xu.
- Obstetrics and Gynecology Department of The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui Province, China. Electronic address: conglin1957@163.com.
- Eur. J. Obstet. Gynecol. Reprod. Biol. 2016 Dec 1; 207: 18-22.
ObjectiveSutures in laparoscopy have been extensively developed in recent years. In this study, we assessed differences between Polysorb™ braided absorbable suture (CL-914) and V-Loc™ barbed suture (V-Loc 180) used in vaginal cuff closure during laparoscopic hysterectomy from various aspects.Study DesignThis paper presented a prospective cohort study of 490 consecutive women underwent total laparoscopic hysterectomy (TLH) performed between January 2013 and September 2015 applying identical procedure technique, with cuff closure approaches selected by surgeons. Data collected included operative time, estimated blood loss, postoperative changes in body temperature, perioperative routine blood parameters changes, total average hospital stay, and postoperative hospital stay. In addition, short-term (at least 6 months) outcomes of vaginal cuff granulomatous (VCG) between the two suture approaches were compared.ResultsBetween groups, statistical differences were detected in operative duration, estimated blood loss, total and postoperative hospital stay, WBC, neutrophil counts and Hb in postoperative routine blood parameters; while there were no significant differences in other data (all P>0.05). Postoperative routine blood parameters in each group: compared to preoperative baseline, in Group 1, WBC, N increased (P<0.05), while RBC, Hb decreased (P<0.05). In Group 2, same tendency in WBC, N and Hb was indicated, but RBC increased with no significant difference. In both groups, vaginal cuff healing was well, with no dehiscence. VCG occurred more often in women used CL-914 than women applied V-Loc 180.ConclusionsV-Loc barbed suture can be used for vaginal cuff closure during TLH due to advantages such as less operative duration and blood loss, shorter postoperative and total hospital stay, and reduced VCG formation six months after TLH.Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.