-
J Magn Reson Imaging · Apr 2019
Evaluation of Normal-Appearing White Matter in Multiple Sclerosis Using Direct Visualization of Short Transverse Relaxation Time Component (ViSTa) Myelin Water Imaging and Gradient Echo and Spin Echo (GRASE) Myelin Water Imaging.
- Joon Yul Choi, In Hye Jeong, Se-Hong Oh, Chang-Hyun Oh, Na Young Park, Ho Jin Kim, and Jongho Lee.
- Laboratory for Imaging Science and Technology, Department of Electrical and Computer Engineering, Seoul National University, Seoul, Republic of Korea.
- J Magn Reson Imaging. 2019 Apr 1; 49 (4): 1091-1098.
BackgroundIn multiple sclerosis (MS), not only lesions but also normal MRI-appearing white matter (NAWM) may undergo demyelination.PurposeTo demonstrate the detection of NAWM demyelination using direct visualization of short transverse relaxation time component myelin water imaging (ViSTa-MWI) and to compare the results with those of conventional gradient echo and spin echo (GRASE)-MWI.Study TypeControl/cohort.PopulationTwenty-five MS patients and 18 healthy controls (HC).Field Strength/Sequence3T/ViSTa and GRASE-MWI.AssessmentUsing ViSTa and GRASE-MWI, myelin water fraction (MWF) of NAWM or normal WM was compared between MS (all patients or early-stage MS patients) and HC. The comparison was performed for a global WM mask and five regional WM masks.Statistical TestsA general linear model was applied for the comparison. A statistical power and a minimum sample size for the significant difference were obtained. Spearman's correlation coefficient was calculated between MWF and clinical measures and between ViSTa-MWF and GRASE-MWF for the global WM mask.ResultsMWFs of ViSTa were significantly lower in the MS patients than those in the HC in all masks (P < 0.001). GRASE-MWI results revealed reduced MWFs only in global WM, genu, and optic radiation. ViSTa-MWI had higher statistical powers than that of GRASE-MWI (power: ViSTa = 99.2 ± 1.6% and GRASE = 75.5 ± 31.0%; sample size: ViSTa = 18 ± 9 and GRASE = 78 ± 75). In early-stage MS, MWFs of ViSTa were significantly lower than those of the HC in all masks except for centrum semiovale; however, MWFs of GRASE MWI were significantly lower only in optic radiation. Disease duration was correlated with both MWIs (ViSTa; r = -0.437 and GRASE; r = -0.445). ViSTa and GRASE MWFs were significantly correlated in the HC (r = 0.664) and MS (r = 0.768).Data ConclusionViSTa-MWI may detect a reduction of MWF in NAWM of MS.Level Of Evidence3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:1091-1098.© 2018 International Society for Magnetic Resonance in Medicine.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.