Paediatric anaesthesia · Sep 2021
Safety and efficacy evaluation of the automatic stepwise recruitment manoeuvre in the neonatal population: An in-vivo interventional study.
- Clara Serrano Zueras, Verónica Guilló Moreno, Martín Santos González, Francisco Javier Gómez Nieto, Göran Hedenstierna, and Javier García Fernández.
- Department of Anaesthesiology, Intensive Care and Pain, Hospital Universitario Puerta de Hierro en Majadahonda, Majadahonda, Spain.
- Paediatr Anaesth. 2021 Sep 1; 31 (9): 1003-1010.
BackgroundA new software has recently been incorporated in almost all new anesthesia machines to enable automatic lung recruitment maneuvers. To date, no studies have assessed the safety and efficacy of these automatic software programs in the neonatal population.AimsWe aimed to evaluate the safety and efficacy of the lung recruitment maneuver performed using the automatic stepwise recruitment maneuver software of the FLOW-i 4.3 Anesthesia System® in a healthy and live neonatal model.MethodsEight male newborn piglets were included in the study. The lung recruitment maneuver was performed in pressure-controlled ventilation with a constant driving pressure (15 cmH2 O) in a stepwise increasing positive end-expiratory pressure (PEEP) model. The target peak inspiratory pressure (PIP) was 30 cmH2 O and PEEP was 15 cmH2 O. The maneuver lasted for 39 seconds. The hemodynamic variables were monitored using the PICCO® system. The following respiratory parameters were monitored: oxygen saturation, fraction of inspired oxygen, partial pressure of oxygen and carbon dioxide in the arterial blood, end-tidal carbon dioxide pressure, PIP, plateau pressure, PEEP, static compliance (Cstat ), and dynamic compliance (Cdyn ). Safety was evaluated by assessing the accuracy of the software, need for not interrupting the maneuver, hemodynamic stability, and absence of adverse respiratory events with the lung recruitment maneuver. Efficacy was evaluated by improvement in Cstat and Cdyn after performing the lung recruitment maneuver.ResultsAll lung recruitment maneuvers were safely performed as scheduled without any interruptions. No pneumothorax or other side effects were observed. Hemodynamic stability was maintained during the lung recruitment maneuver. We observed an improvement of 33% in Cdyn and 24% in Cstat after the maneuver.ConclusionsThe automatic stepwise recruitment maneuver software of the FLOW-i 4.3 Anesthesia System® is safe and efficacious in a healthy neonatal model. We did not observe any adverse respiratory or hemodynamic events during the implementation of the lung recruitment maneuver in the pressure-controlled ventilation mode using a stepwise increasing PEEP (30/15 cmH2 O) approach.© 2021 John Wiley & Sons Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.