Ultrasound Obstet Gynecol · Feb 2014
Multicenter Study Observational StudySonographic prediction of vaginal delivery in prolonged labor: a two-center study.
- T M Eggebø, W A Hassan, K Å Salvesen, E Lindtjørn, and C C Lees.
- Department of Obstetrics and Gynecology, Stavanger University Hospital, Stavanger, Norway; National Center for Fetal Medicine, Trondheim University Hospital (St Olavs Hospital), Trondheim, Norway.
- Ultrasound Obstet Gynecol. 2014 Feb 1; 43 (2): 195-201.
ObjectiveTo investigate whether head-perineum distance (HPD) measured by transperineal ultrasound is predictive of vaginal delivery and time remaining in labor in nulliparous women with prolonged first stage of labor and to compare the predictive value with that of angle of progression (AoP).MethodsThis was a prospective observational study at Stavanger University Hospital, Norway and Addenbrooke's Hospital, Cambridge, UK from January 2012 to April 2013, of nulliparous women with singleton pregnancies with cephalic presentation at term with prolonged first stage of labor. We used transperineal ultrasound to measure HPD (shortest distance between the outer bony limit of the fetal skull and the perineum) and AoP (angle between a line through the long axis of the symphysis and the tangent to the fetal head) and transabdominal ultrasound to classify fetal head position. The main outcomes were vaginal delivery and time remaining in labor.ResultsOf 150 women enrolled, 39 underwent delivery by Cesarean section. The area under the receiver-operating characteristics curve for the prediction of vaginal delivery was 81% (95% CI, 73-89%) using HPD as the test variable and 72% (95% CI, 63-82%) using AoP. HPD was ≤ 40 mm in 84 (56%) women, of whom 77 (92%; 95% CI, 84-96%) delivered vaginally. HPD was > 40 mm in the other 66 (44%) women, of whom 34 (52%; 95% CI, 40-63%) delivered vaginally. AoP was ≥ 110° in 84 of the 145 (58%) in whom this was available and, of these, 74 (88%; 95% CI, 79-93%) delivered vaginally. AoP was < 110° in the other 61 (42%) women, of whom 35 (57%; 95% CI, 45-69%) delivered vaginally. Multivariable logistic regression analysis showed that HPD ≤ 40 mm (odds ratio (OR), 4.92; 95% CI, 1.54-15.80), AoP ≥ 110° (OR, 3.11; 95% CI, 1.01-9.56), non-occiput posterior position (OR, 3.36; 95% CI, 1.24-9.12) and spontaneous onset of labor (OR, 4.44; 95% CI, 1.42-13.89) were independent predictors for vaginal delivery. Both ultrasound methods were predictive for the time remaining in labor.ConclusionTransperineal ultrasound measurement of HPD and AoP provide important information about the likelihood of vaginal delivery and the time remaining in labor in nulliparous women with prolonged labor.Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.