-
J Magn Reson Imaging · Aug 2010
3D flow-independent peripheral vessel wall imaging using T(2)-prepared phase-sensitive inversion-recovery steady-state free precession.
- Jingsi Xie, Xiaoming Bi, Zhaoyang Fan, Himanshu Bhat, Saurabh Shah, Sven Zuehlsdorff, and Debiao Li.
- Department of Radiology, Northwestern University, Chicago, Illinois, USA.
- J Magn Reson Imaging. 2010 Aug 1; 32 (2): 399-408.
PurposeTo develop a 3D flow-independent peripheral vessel wall imaging method using T(2)-prepared phase-sensitive inversion-recovery (T(2)PSIR) steady-state free precession (SSFP).Materials And MethodsA 3D T(2)-prepared and nonselective inversion-recovery SSFP sequence was designed to achieve flow-independent blood suppression for vessel wall imaging based on T(1) and T(2) properties of the vessel wall and blood. To maximize image contrast and reduce its dependence on the inversion time (TI), phase-sensitive reconstruction was used to restore the true signal difference between vessel wall and blood. The feasibility of this technique for peripheral artery wall imaging was tested in 13 healthy subjects. Image signal-to-noise ratio (SNR), wall/lumen contrast-to-noise ratio (CNR), and scan efficiency were compared between this technique and conventional 2D double inversion recovery - turbo spin echo (DIR-TSE) in eight subjects.Results3D T(2)PSIR SSFP provided more efficient data acquisition (32 slices and 64 mm in 4 minutes, 7.5 seconds per slice) than 2D DIR-TSE (2-3 minutes per slice). SNR of the vessel wall and CNR between vessel wall and lumen were significantly increased as compared to those of DIR-TSE (P < 0.001). Vessel wall and lumen areas of the two techniques are strongly correlated (intraclass correlation coefficients: 0.975 and 0.937, respectively; P < 0.001 for both). The lumen area of T(2)PSIR SSFP is slightly larger than that of DIR-TSE (P = 0.008). The difference in vessel wall area between the two techniques is not statistically significant.ConclusionT(2)PSIR SSFP is a promising technique for peripheral vessel wall imaging. It provides excellent blood signal suppression and vessel wall/lumen contrast. It can cover a 3D volume efficiently and is flow- and TI-independent.2010 Wiley-Liss, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.