-
- Chathura Kumaragamage, Dan Madularu, Axel P Mathieu, Henk De Feyter, M Natasha Rajah, and Jamie Near.
- Department of Biomedical Engineering, McGill University, Montreal, QC, Canada.
- Magn Reson Med. 2018 Feb 1; 79 (2): 628-635.
PurposeIn vivo carbon-13 (13 C) MR spectroscopy (MRS) is capable of measuring energy metabolism and neuroenergetics, noninvasively in the brain. Indirect (1 H-[13 C]) MRS provides sensitivity benefits compared with direct 13 C methods, and normally includes a 1 H surface coil for both localization and signal reception. The aim was to develop a coil platform with homogenous B1+ and use short conventional pulses for short echo time proton observed carbon edited (POCE) MRS.MethodsA 1 H-[13 C] MRS coil platform was designed with a volumetric resonator for 1 H transmit, and surface coils for 1 H reception and 13 C transmission. The Rx-only 1 H surface coil nullifies the requirement for a T/R switch before the 1 H preamplifier; the highpass filter and preamplifier can be placed proximal to the coil, thus minimizing sensitivity losses inherent with POCE-MRS systems described in the literature. The coil platform was evaluated with a PRESS-POCE sequence (TE = 12.6 ms) on a rat model.ResultsThe coil provided excellent localization, uniform spin nutation, and sensitivity. 13 C labeling of Glu-H4 and Glx-H3 peaks, and the Glx-H2 peaks were observed approximately 13 and 21 min following the infusion of 1-13 C glucose, respectively.ConclusionA convenient and sensitive platform to study energy metabolism and neurotransmitter cycling is presented. Magn Reson Med 79:628-635, 2018. © 2017 International Society for Magnetic Resonance in Medicine.© 2017 International Society for Magnetic Resonance in Medicine.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.