• J Magn Reson Imaging · Sep 2003

    T 1 rho-relaxation mapping of human femoral-tibial cartilage in vivo.

    • Ravinder Reddy Regatte, Sarma V S Akella, Andrew J Wheaton, Arijitt Borthakur, J Bruce Kneeland, and Ravinder Reddy.
    • Metabolic Magnetic Resonance Research and Computing Center (MMRRCC), Department of Radiology, Stellar-Chance Laboratories, University of Pennsylvania Medical Center, Philadelphia, Pennsylvania 19104-6100, USA. regatte@mail.mmrrcc.upenn.edu
    • J Magn Reson Imaging. 2003 Sep 1; 18 (3): 336-41.

    PurposeTo demonstrate the in vivo feasibility of measuring spin-lattice relaxation time in the rotating frame (T(1rho)); and T(1rho)-dispersion in human femoral cartilage. Furthermore, we aimed to compute the baseline T(1rho)-relaxation times and spin-lock contrast (SLC) maps on healthy volunteers, and compare relaxation times and signal-to-noise ratio (SNR) with corresponding T(2)-weighted images.Materials And MethodsAll MR imaging experiments were performed on a 1.5 T GE Signa scanner (GEMS, Milwaukee, WI) using a custom built 15-cm transmit-receive quadrature birdcage radio-frequency (RF) coil. The T(1rho)-prepared magnetization was imaged with a single-slice two-dimensional fast spin-echo (FSE) pulse sequence preencoded with a three-pulse cluster consisting of two hard 90 degrees pulses and a low power spin-lock pulse. T(1rho)-dispersion imaging was performed by varying the spin-lock frequency from 100 to 500 Hz in five steps in addition to varying the length of the spin-lock pulse.ResultsThe average T(1rho)-relaxation times in the weight-bearing (WB) and nonweight-bearing (NWB) regions of the femoral condyle were 42.2 +/- 3.6 msec and 55.7 +/- 2.3 msec (mean +/- SD, N = 5, P < 0.0001), respectively. In the same regions, the corresponding T(2)-relaxation times were 31.8 +/- 1.5 msec and 37.6 +/- 3.6 msec (mean +/- SD, N = 5, P < 0.0099). T(1rho)-weighted images have approximately 20%-30% higher SNR than the corresponding T(2)-weighted images for similar echo time. The average SLC in the WB region of femoral cartilage was 30 +/-4.0%. Furthermore, SLC maps provide better contrast between fluid and articular surface of femoral-tibial joint than T(1rho)-maps. The T(1rho)-relaxation times varied from 32 msec to 42 msec ( approximately 31%) in the WB and 37 msec to 56 msec ( approximately 51%) in NWB regions of femoral condyle, respectively, in the frequency range 0-500 Hz (T(1rho)-dispersion).ConclusionThe feasibility of performing in vivo T(1rho) relaxation mapping in femoral cartilage at 1.5T clinical scanner without exceeding Food and Drug Administration (FDA) limits on specific absorption rate (SAR) of RF energy was demonstrated.Copyright 2003 Wiley-Liss, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…