• Investigative radiology · Sep 2009

    Three-dimensional T2-weighted MRI of the human femoral arterial vessel wall at 3.0 Tesla.

    • Zhuoli Zhang, Zhaoyang Fan, Timothy J Carroll, YiuCho Chung, Peter Weale, Renate Jerecic, and Debiao Li.
    • Department of Radiology, Northwestern University, Chicago, IL, USA.
    • Invest Radiol. 2009 Sep 1; 44 (9): 619-26.

    ObjectivesTo evaluate the potential use of a novel 3D turbo spin-echo (TSE) T2-weighted (T2w) technique for assessing the vessel wall in the superficial femoral artery at 3.0 T.BackgroundMagnetic resonance imaging can be used for the noninvasive assessment of atherosclerotic plaque burden in the peripheral circulation. Although black-blood 2D TSE techniques have been used for femoral arterial wall imaging, these techniques require prolonged imaging time to cover a large field of view required to cover the leg. Recently, variable-flip-angle 3D TSE T2w (SPACE) has been introduced as a fast vessel wall imaging technique with submillimeter spatial resolution. A systematic investigation of the application of this technique to femoral arterial wall imaging has yet to be performed.MethodsFifteen healthy volunteers and 3 patients with peripheral arterial disease (PAD) underwent 3D SPACE imaging of the superficial femoral artery at 3.0 T, with the conventional 2D TSE T2w imaging as a reference. Muscle-lumen contrast to noise ratio (CNR) and wall/lumen volumes (WV, LV) were measured at the matched locations on the 3D and 2D image sets. Statistical comparison on a per-subject basis was conducted to determine the difference and agreement between 3D SPACE and the 2D TSE techniques.ResultsThe 3D SPACE data sets enabled vessel visualization from arbitrary orientation through multiplanar reformation technique. Muscle-lumen CNR was significantly higher with 3D SPACE than with the 2D TSE (3.12 +/- 0.84 vs. 2.17 +/- 0.34, P < 0.01). This trend was confirmed when CNR efficiency (CNR(eff)) values were further compared. A similar trend was observed in PAD patients (SPACE vs. 2D TSE T2w: CNR 2.35 +/- 0.13 vs. 1.77 +/- 0.25; CNR(eff) 15.35 +/- 0.61 vs. 3.59 +/- 2.62. all P < 0.05). Measurements of WV and LV from the 3D and 2D techniques were highly correlated in volunteers and PAD patients (volunteers, WV: linear regression r2 = 0.98, LV: r2 = 0.98, P < 0.001 for both; patients, WV: linear regression r2 = 0.96, LV: r2 = 0.94, P < 0.001 for both).ConclusionWe established the feasibility of using the 3D SPACE technique for vessel wall imaging in the superficial femoral artery at 3.0T. High, isotropic-resolution SPACE images, with the aid of multiplanar reformation, enable superior vessel wall visualization. Superior blood signal suppression comparable to vessel wall morphologic measurements, and superior time efficiency compared to conventional 2D TSE imaging indicate the great potential of the SPACE method as a noninvasive imaging technique for the assessment of atherosclerotic plaque burden in PAD patients.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…