• J. Endovasc. Ther. · Feb 2011

    Clinical Trial

    Cardiva Catalyst II vascular access management device in percutaneous diagnostic and interventional procedures with same-day discharge (Catalyst II trial).

    • R Stefan Kiesz, Barbara K Wiernek, Szymon L Wiernek, Charlotte Merritt, Tomas Ybarra, Adam Iwanski, Piotr P Buszman, Radoslaw Szymanski, Jack L Martin, and Pawel E Buszman.
    • San Antonio Endovascular & Heart Institute, San Antonio, Texas 78258, USA. rs.kiesz@sbcglobal.net
    • J. Endovasc. Ther. 2011 Feb 1; 18 (1): 46-53.

    PurposeTo present a prospective, single-center trial of the Cardiva Catalyst II, a vascular closure device that provides temporary hemostasis after the procedure and is removed under manual compression, leaving no material behind.MethodsDuring a 16-month period between April 2008 and July 2009, 400 procedures (100 interventions, 300 diagnostic procedures) were performed on 351 nonconsecutive patients (185 men; mean age 60.2 ± 12.0 years, range 27-93). All interventions were performed utilizing bivalirudin for anti-thrombin therapy. Initial follow-up was done at a mean 1.3 ± 0.7 days after the index procedure in all patients. Final follow-up, for diagnostic procedures as well as interventions, was performed at a mean 15.4 ± 7.1 days. The primary and secondary endpoints were the rate of major and minor vascular complications, respectively.ResultsSuccessful deployment of the device was reported in 397 (99.3%) procedures, which were primarily in retrograde fashion (97.0%) from the right groin (92.5%). In most cases (309, 77.2%), a 5-F sheath was used. A major vascular complication occurred after 1 intervention; none was noted after diagnostic procedures. Minor vascular complications were recorded after 2 interventions and 5 diagnostic procedures. Overall vascular complication rates were 0.25% for major sequelae and 1.75% for minor events. Mean time to discharge after diagnostic procedures was 145.0 ± 21.2 minutes versus 295.1 ± 44.1 minutes after interventional procedures (p < 0.05). There was no death, stroke, myocardial infarction, or urgent hospital transfer in the study cohort.ConclusionCardiva Catalyst is safe and effective device in achieving local hemostasis after percutaneous diagnostic procedures and interventions performed under bivalirudin anticoagulation. The use of this device with an appropriate protocol facilitates same-day discharge.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…