-
J Vasc Interv Radiol · Jun 2008
Comparative StudyComparison of cutting balloon versus high-pressure balloon angioplasty for resistant venous stenoses of native hemodialysis fistulas.
- Chih-Cheng Wu, Ming-Chih Lin, Shih-Yun Pu, Kuei-Chin Tsai, and Szu-Chi Wen.
- Department of Medicine, Hsinchu General Hospital, No. 25, Ln 442, Sec 1, Jingguo Rd, Hsinchu City 300, Taiwan.
- J Vasc Interv Radiol. 2008 Jun 1; 19 (6): 877-83.
PurposeTo compare the technical success, safety, and patency of cutting balloon angioplasty versus high-pressure balloon angioplasty in the treatment of resistant native hemodialysis fistula stenoses.Materials And MethodsThe authors retrospectively reviewed 1,220 percutaneous transluminal angioplasty procedures performed to treat dysfunctional native hemodialysis fistulas. Seventy patients with stenoses resistant to conventional balloon angioplasty (up to 24 atm) were included in this study: 35 patients underwent cutting balloon angioplasty from September 2003 through February 2005, and 35 patients underwent high-pressure balloon angioplasty from March 2005 through April 2006. Evaluation included technical success, complications, and postintervention patency rates up to 6 months.ResultsThe technical success rates were similar between the cutting balloon (100%) and high-pressure balloon (97.1%) groups. After cutting balloon angioplasty, the primary lesion patency rates were 100% (35/35), 88.6% (31/35), and 71.4% (25/35) at 1 month, 3 months, and 6 months, respectively. After high-pressure balloon angioplasty, the primary lesion patency rates were 97.1% (34/35), 62.9% (22/35), and 42.9% (15/35) respectively. The primary lesion patency rates at 3 and 6 months were significantly better with cutting balloon angioplasty than with high-pressure balloon angioplasty (P = .018 and .009, respectively). There were no device-related complications in the cutting balloon group. Six device-related extravasations occurred in the high-pressure balloon group.ConclusionsThe results of this retrospective study suggest that, for resistant stenoses in native hemodialysis fistulas, both high-pressure balloon and cutting balloon angioplasty are effective; however, cutting balloon angioplasty seems to provide more long-standing primary patency at 6-month follow-up.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.