-
Investigative radiology · Oct 2017
Compressed Sensing for Breast MRI: Resolving the Trade-Off Between Spatial and Temporal Resolution.
- Suzan Vreemann, Alejandro Rodriguez-Ruiz, Dominik Nickel, Laura Heacock, Linda Appelman, Jan van Zelst, Nico Karssemeijer, Elisabeth Weiland, Marnix Maas, Linda Moy, Berthold Kiefer, and Ritse M Mann.
- From the *Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, the Netherlands; †MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany; and ‡Department of Radiology, Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, New York, NY.
- Invest Radiol. 2017 Oct 1; 52 (10): 574-582.
ObjectiveUltrafast dynamic contrast-enhanced magnetic resonance imaging of the breast enables assessment of the contrast inflow dynamics while providing images with diagnostic spatial resolution. However, the slice thickness of common ultrafast techniques still prevents multiplanar reconstruction. In addition, some temporal blurring of the enhancement characteristics occurs in case view-sharing is used. We evaluate a prototype compressed-sensing volume-interpolated breath-hold examination (CS-VIBE) sequence for ultrafast breast MRI that improves through plane spatial resolution and avoids temporal blurring while maintaining an ultrafast temporal resolution (less than 5 seconds per volume). Image quality (IQ) of the new sequence is compared with an ultrafast view-sharing sequence (time-resolved angiography with interleaved stochastic trajectories [TWIST]), and assessment of lesion morphology is compared with a regular T1-weighted 3D Dixon sequence (VIBE-DIXON) with an acquisition time of 91 seconds.Materials And MethodsFrom April 2016 to October 2016, 30 women were scanned with the CS-VIBE sequence, replacing the routine ultrafast TWIST sequence in a hybrid breast MRI protocol. The need for informed consent was waived. All MRI scans were performed on a 3T MAGNETOM Skyra system (Siemens Healthcare, Erlangen, Germany) using a 16-channel bilateral breast coil. Two reader studies were conducted involving 5 readers. In the first study, overall IQ of CS-VIBE and TWIST in the axial plane was independently rated for 23 women for whom prior MRI examinations with TWIST were available. In addition, the presence of several types of artifacts was rated on a 5-point scale. The second study was conducted in women (n = 16) with lesions. In total, characteristics of 31 lesions (5 malignant and 26 benign) were described independently for CS-VIBE and VIBE-DIXON, according to the BI-RADS MRI-lexicon. In addition, a lesion conspicuity score was given.ResultsUsing CS-VIBE, a much higher through-plane spatial resolution was achieved in the same acquisition time as with TWIST, without affecting in-plane IQ (P = 0.260). Time-resolved angiography with interleaved stochastic trajectories showed slightly more motion artifacts and infolding and ghosting artifacts compared with CS-VIBE, whereas CS-VIBE showed more breathing and pulsation artifacts. For morphologic assessment, intrareader agreement between CS-VIBE and the more time-consuming VIBE-DIXON was slight to almost perfect, and generally higher than interreader agreement. Mean sensitivity (84.0% and 92.0% for CS-VIBE and VIBE-DIXON, P = 0.500) and specificity (60.0% and 55.4% for CS-VIBE and VIBE-DIXON, P = 0.327) were comparable for both sequences.ConclusionsCompressed-sensing volume-interpolated breath-hold examination allows an increase of the through-plane spatial resolution of ultrafast dynamic contrast-enhanced magnetic resonance imaging compared with TWIST at a comparable in-plane IQ. Morphological assessment of lesions using CS-VIBE is comparable to VIBE-DIXON, which takes 18 times longer. Consequently, CS-VIBE enables 3D evaluation of breast lesions in ultrafast breast MRI.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.