-
Diagn Interv Imaging · Mar 2017
Comparative StudyPreoperative grading of supratentorial gliomas using high or standard b-value diffusion-weighted MR imaging at 3T.
- M M Cihangiroglu, E Ozturk-Isik, Z Firat, O Kilickesmez, A M Ulug, and U Ture.
- Bahçeşehir University, Department of Radiology, Medical Park Göztepe Hospital, Merdivenköy, Kadıköy, 34000 İstanbul, Turkey. Electronic address: mmutlucihan@hotmail.com.
- Diagn Interv Imaging. 2017 Mar 1; 98 (3): 261-268.
PurposeThe goal of this study was to compare diffusion-weighted magnetic resonance imaging (DW-MRI) using high b-value (b=3000s/mm2) to DW-MRI using standard b-value (b=1000s/mm2) in the preoperative grading of supratentorial gliomas.Materials And MethodsFifty-three patients with glioma had brain DW-MRI at 3T using two different b-values (b=1000s/mm2 and b=3000s/mm2). There were 35 men and 18 women with a mean age of 40.5±17.1 years (range: 18-79 years). Mean, minimum, maximum, and range of apparent diffusion coefficient (ADC) values for solid tumor ROIs (ADCmean, ADCmin, ADCmax, and ADCdiff), and the normalized ADC (ADCratio) were calculated. A Kruskal-Wallis statistic with Bonferroni correction for multiple comparisons was applied to detect significant ADC parameter differences between tumor grades by including or excluding 19 patients with an oligodendroglioma. Receiver operating characteristic curve analysis was conducted to define appropriate cutoff values for grading gliomas.ResultsNo differences in ADC derived parameters were found between grade II and grade III gliomas. Mean ADC values using standard b-value were 1.17±0.27×10-3mm2/s [range: 0.63-1.61], 1.05±0.22×10-3mm2/s [range: 0.73-1.33], and 0.86±0.23×10-3mm2/s [range: 0.52-1.46] for grades II, III and IV gliomas, respectively. Using high b-value, mean ADC values were 0.89±0.24×10-3mm2/s [range: 0.42-1.25], 0.82±0.20×10-3mm2/s [range: 0.56-1.10], and 0.59±0.17×10-3mm2/s [range: 0.40-1.01] for grades II, III and IV gliomas, respectively. ADCmean, ADCratio, ADCmax, and ADCmin were different between grade II and grade IV gliomas at both standard and high b-values. Differences in ADCmean, ADCmax, and ADCdiff were found between grade III and grade IV only using high b-value.ConclusionADC parameters derived from DW-MRI using a high b-value allows a better differential diagnosis of gliomas, especially for differentiating grades III and IV, than those derived from DW-MRI using a standard b-value.Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.