• Radiology · Feb 2014

    Arterial, venous, and cerebrospinal fluid flow: simultaneous assessment with Bayesian multipoint velocity-encoded MR imaging.

    • Verena Knobloch, Christian Binter, Vartan Kurtcuoglu, and Sebastian Kozerke.
    • From the Institute for Biomedical Engineering, University and ETH Zurich, Gloriastrasse 35, 8092 Zurich, Switzerland (V. Knobloch, C.B., S.K.); the Interface Group, Institute of Physiology, University of Zurich, Zurich, Switzerland (V. Kurtcuoglu); and Division of Imaging Sciences and Biomedical Engineering, King's College London, London, England.
    • Radiology. 2014 Feb 1; 270 (2): 566-73.

    PurposeTo measure arterial, venous, and cerebrospinal fluid (CSF) velocities simultaneously by using Bayesian multipoint velocity-encoded magnetic resonance (MR) imaging and to compare interacquisition reproducibility relative to that of standard phase-contrast MR imaging for sequential measurements of arterial, venous, and CSF velocities.Materials And MethodsThis study was approved by the local ethics committee, and informed consent was obtained from all subjects. Simultaneous measurement of blood and CSF flow was performed at the C1-C2 level in 10 healthy subjects (mean age, 24.4 years ± 2.7; five men, five women) by using accelerated Bayesian multipoint velocity-encoded MR imaging. Data were compared with those obtained from two separate conventional phase-contrast MR imaging acquisitions, one optimized for arterial and venous blood flow (velocity encoding range, ±50 cm/sec) and the other optimized for CSF flow (velocity encoding range, ±10 cm/sec), with an imaging time of approximately 2 minutes each. Data acquisition was repeated six times. Intraclass correlation coefficient (ICC) and linear regression were used to quantify interacquisition reproducibility.ResultsThere was no significant difference in arterial blood flow measured with Bayesian multipoint velocity-encoded MR imaging and that measured with phase-contrast MR imaging (mean ICC, 0.96 ± 0.03 vs 0.97 ± 0.02, respectively). Likewise, there was no significant difference between CSF flow measured with Bayesian multipoint velocity-encoded MR imaging and that measured with phase-contrast MR imaging (mean ICC, 0.97 ± 0.02 vs 0.96 ± 0.05, respectively). For venous blood flow, the ICC with Bayesian multipoint MR imaging was significantly larger than that with conventional phase-contrast MR imaging (mean, 0.75 ± 0.23 vs 0.65 ± 0.26, respectively; P = .016).ConclusionBayesian multipoint velocity-encoded MR imaging allows for simultaneous assessment of fast and slow flows in arterial, venous, and CSF lumina in a single acquisition. It eliminates the need for vessel-dependent adjustment of the velocity-encoding range, as required for conventional sequential phase-contrast MR imaging measurements.© RSNA, 2013.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…