• Nuklearmed Nucl Med · Apr 1999

    [Reduction of radiation exposure in PET examinations by data acquisition in the 3D mode].

    • G Brix, L E Adam, J Zaers, H Trojan, M E Bellemann, D Nosske, and J Doll.
    • Abteilung für Medizinische Strahlenhygiene und nichtionisierende Strahlung, Institut für Strahlenhygiene, Neuherberg. gbrix@bfs.de
    • Nuklearmed Nucl Med. 1999 Apr 1; 38 (3): 75-9.

    AimModern volume PET systems offer the possibility to measure without the shadowing effect of interplane septa (2D mode) and thus to detect coincident events between detectors on distant rings (3D mode). It was the aim of the present paper to characterize the count rate behaviour of a latest-generation whole-body PET system in the 2D and 3D mode as well as to discuss the consequences for the radiation hygiene of PET examinations with 2-[F-18]-fluoro-2-deoxyglucose (18-F-FDG).MethodsAll experiments were performed with the PET system ECAT EXACT HR+. For 2D data acquisition, a collimator of thin tungsten septa was positioned in the field-of-view. The count rate behaviour of the scanner was evaluated in the 2D and 3D mode over a wide range of F-18 activity concentrations following the NEMA protocol. Moreover, PET images of the EEC whole-body phantom with different inserts were acquired in the 2D and 3D mode over a period of 15 min each. For the 3D measurement, the activity concentrations of the F-18 solution were only half of those used for the 2D measurement.ResultsFor the circular NEMA phantom (phi = 19.4 cm, length = 19.0 cm), we observed an increase of the system sensitivity in the 3D mode by a factor of about 5 with respect to the 2D mode (27.7 vs. 5.7 cps/Bq/ml). The evaluation of the activity distributions of the EEC phantom reconstructed from the 3D data set revealed a superior image quality compared to the corresponding 2D images despite the fact that the activity concentrations were only half as high.ConclusionsBy using the 3D data acquisition mode, it is possible to markedly reduce the amount of activity to be applied to the patient and nevertheless to improve image quality. In our experience, it is sufficient to administer an activity of 150-200 MBq for whole-body examinations with F-18-FDG, which results in an effective equivalent dose of 3 or 4 mSv, respectively.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.