• Interv Neuroradiol · Jun 2017

    Case Reports

    Treatment of an internal carotid artery aneurysm with a flow diverter through a double lumen balloon catheter.

    • José M Amorim, Santiago Rosati, Ronit Agid, Vítor Mendes Pereira, and Timo Krings.
    • 1 Neuroradiology Department, Hospital de Braga, Braga, Portugal.
    • Interv Neuroradiol. 2017 Jun 1; 23 (3): 255-259.

    AbstractBackground Double lumen balloon catheters (DLBCs) are currently used in the treatment of intracranial aneurysms, especially when involving balloon or stent-assisted coiling. The existing DLBCs allow the delivery of self-expandable stents but do not offer the possibility to deploy flow-diverters. Despite the increasing use and success of flow-diverters, there have been numerous reports of procedural complications such as early in-stent thrombosis or delayed distal embolization. It seems that these complications can be avoided by correct stent positioning and adequate wall apposition, achieved either by manoeuvres with the microguidewire and/or microcatheter or by performing balloon angioplasty following an exchange guidewire manoeuvre. Objective Report the use of a new DLBC able to deliver a flow-diverter. Methods A 41-year-old woman presented to our hospital with binocular horizontal diplopia for two weeks and reduced visual acuity. A left internal carotid artery aneurysm involving the cavernous and ophthalmic segments was found, with a maximum height of 19 mm and a broad 8 mm neck. It presented extra- and intra-dural components and the parent vessel was significantly narrowed. A decision was made to perform endovascular treatment of the aneurysm with placement of a flow diverter through a DLBC. Results Patency and adequate expansion of the flow diverter with evident intra-aneurysmal contrast stasis was observed in the final angiogram. No peri-procedural complications were observed. Conclusion This is a technical note demonstrating the feasibility of a new device to deploy a flow diverter, aiming to improve wall apposition and stent configuration without the need of additional devices or exchange manoeuvres.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…