-
Am. J. Respir. Crit. Care Med. · Sep 2021
Randomized Controlled TrialPhysiological Traits and Adherence to Therapy of Sleep Apnea in Individuals with Coronary Artery Disease.
- Andrey V Zinchuk, Jen-Hwa Chu, Jiasheng Liang, Yeliz Celik, Sara Op de Beeck, Nancy S Redeker, Andrew Wellman, H Klar Yaggi, Yüksel Peker, and Scott A Sands.
- Department of Internal Medicine, School of Medicine.
- Am. J. Respir. Crit. Care Med. 2021 Sep 15; 204 (6): 703-712.
AbstractRationale: Untreated obstructive sleep apnea (OSA) is associated with adverse outcomes in patients with coronary artery disease (CAD). Continuous positive airway pressure (CPAP) is the most common treatment, but despite interventions addressing established adherence determinants, CPAP use remains poor. Objectives: To determine whether physiological traits that cause OSA are associated with long-term CPAP adherence in patients with CAD. Methods: Participants in the RICCADSA (Randomized Intervention with CPAP in CAD and OSA) trial with objective CPAP adherence (h/night) over 2 years and analyzable raw polysomnography data were included (N = 249). The physiological traits-loop gain, arousal threshold (ArTH), pharyngeal collapsibility (Vpassive), and pharyngeal muscle compensation (Vcomp)-were measured by using polysomnography. Linear mixed models were used to assess the relationship between the traits and adherence. We also compared actual CPAP adherence between those with physiologically predicted "poor" adherence (lowest quartile of predicted adherence) and those with physiologically predicted "good" adherence (all others). Measurements and Main Results: The median (interquartile range) CPAP use declined from 3.2 (1.0-5.8) h/night to 3.0 (0.0-5.6) h/night over 24 months (P < 0.001). In analyses adjusted for demographics, anthropometrics, OSA characteristics, and clinical comorbidities, a lower ArTH was associated with worse CPAP adherence (0.7 h/SD of the ArTH; P = 0.021). Both high and low Vcomp were associated with lower adherence (P = 0.008). Those with predicted poor adherence exhibited markedly lower CPAP use than those with predicted good adherence for up to 2 years of follow-up (group differences of 2.0-3.2 h/night; P < 0.003 for all). Conclusions: A low ArTH, as well as a very low and high Vcomp, are associated with worse long-term CPAP adherence in patients with CAD and OSA. Physiological traits-alongside established determinants-may help predict and improve CPAP adherence. Clinical trial registered with www.clinicaltrials.gov (NCT00519597).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.