- Chisa Hosokawa, Kazunari Ishii, Yuichi Kimura, Tomoko Hyodo, Makoto Hosono, Kenta Sakaguchi, Kimio Usami, Kenji Shimamoto, Yuzuru Yamazoe, and Takamichi Murakami.
- Department of Radiology, Kinki University Faculty of Medicine, Osakasayama, Osaka, Japan Institute of Advanced Clinical Medicine, Kinki University Faculty of Medicine, Osakasayama, Osaka, Japan ch4111@gmail.com.
- J. Nucl. Med. 2015 Dec 1; 56 (12): 1910-5.
UnlabelledThe goal of this study was to clarify whether binding potential (BP) images using (11)C-Pittsburgh compound B ((11)C-PiB) and dynamic PET can reliably detect cortical amyloid deposits for patients whose (11)C-PiB PET static images are ambiguous and whether visual ratings are affected by white matter retention.MethodsStatic and BP images were constructed for 85 consecutive patients with cognitive impairment after (11)C-PiB dynamic PET. Cortical uptake was visually assessed as positive, negative, or equivocal for both types of images. Quantitatively, the standardized uptake value ratio (SUVR) from the static image, the nondisplaceable BP from the dynamic image for mean gray matter uptake, and the ratio of gray matter uptake to white matter retention were compared among (11)C-PiB-positive, (11)C-PiB-equivocal, and (11)C-PiB-negative groups.ResultsForty-three scans were visually assessed as (11)C-PiB-positive in both the static and the BP images. Ten scans were (11)C-PiB-equivocal in the static images. In 8 of them, the BP images were (11)C-PiB-positive, whereas the other 2 were (11)C-PiB-equivocal. Thirty-two scans were assessed as (11)C-PiB-negative in the static images. In the BP images, 4 were (11)C-PiB-positive and 2 were (11)C-PiB-equivocal. The mean gray matter uptake of (11)C-PiB in SUVR and nondisplaceable BP, respectively, showed statistically significant differences among the (11)C-PiB-positive, (11)C-PiB-equivocal, and (11)C-PiB-negative groups. The ratio of gray matter uptake to white matter retention was lower in the BP images than static images from the (11)C-PiB-negative and (11)C-PiB-equivocal groups, whereas it was higher in the (11)C-PiB-positive group.Conclusion(11)C-PiB PET BP images can clarify visual interpretation of clinical static (11)C-PiB-equivocal images by reducing the interference of nonspecific white matter retention. We conclude that (11)C-PiB-equivocal PET findings on static images reflect cortical amyloid deposits, which can be verified using BP images. Furthermore, quantitative assessments, such as SUVR and nondisplaceable BP, are of no use for correctly rating equivocal visual findings.© 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.