• Nucl Med Commun · Sep 2004

    Comparative Study Clinical Trial Controlled Clinical Trial

    Measurement of the extraction fractions of nanocolloid and polyclonal immunoglobulin by axillary lymph nodes in patients with breast cancer.

    • J Charlotte Fowler, Chandra K Solanki, Robert W Barber, E Anna Swift, Ilonka Guenther, James R Ballinger, Arnie D Purushotham, and A Michael Peters.
    • Department of Nuclear Medicine, Addenbrooke's Hospital, Hills Road, Cambridge CB2 2QQ, UK.
    • Nucl Med Commun. 2004 Sep 1; 25 (9): 935-40.

    Background99mTc nanocolloid (99mTc-NC) is the most widely used tracer for lymphoscintigraphy, although others have been proposed, including radiolabelled proteins such as human serum albumin and polyclonal human immunoglobulin G (HIG). The extraction fraction of such tracers by individual nodes is clearly important but has not previously been measured in humans.MethodsPatients scheduled for axillary clearance surgery (three groups) received dual-labelled radiotracers 2-4 h before surgery: group 1 (3 patients) received 99mTc-NC (10 MBq) and 111In-HIG (2 MBq) as a mixture (0.2 ml) into the breast parenchyma above the primary tumour; group 2 (3 patients) received 99mTc-HIG (10 MBq) and 111In-HIG (2 MBq) as a mixture (0.2 ml) into the breast parenchyma above the primary tumour; and group 3 (4 patients) received 99mTc-HIG (10 MBq) and 111In-HIG (2 MBq) separately (both 0.2 ml) into the breast parenchyma above the tumour and the intradermal plane at the areola. All resected nodes were counted for Tc and In in a well-type scintillation counter. In group 1, nodes were ranked according to their Tc uptake. In groups 2 and 3, nodes were ranked separately according to their respective Tc and In uptakes. If nodes are arranged in linear order and each node extracts a constant fraction of incoming tracer, then the activity in the nodes would decrease exponentially with an individual nodal extraction fraction, E, equal to 1-e(-k), where k is the rate constant of decrease.ResultsIn the first group, 99mTc-NC and 111In-HIG identified the same sentinel and second echelon nodes. The observed decrease in nodal activity was exponential in all groups, at least for the first five nodes. Average values for E, based on the first five nodes were 0.69 (range 0.57-0.89; n=3) for 99mTc-NC and 0.45 (0.15-0.70; n=17) for HIG (irrespective of label) (Wilcoxon rank sum, P=0.02). With respect to HIG, there was no significant difference in E between 99mTc and 111In or between deep and superficial injections in group 3.ConclusionAlthough HIG has an extraction fraction less than 99mTc-NC, the value of E is still high enough to make HIG a useful tracer for lymphoscintigraphy, especially for identifying second echelon nodes in addition to sentinel nodes and for imaging lymphatic vessels as well as lymph nodes.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.