• J Magn Reson Imaging · Apr 2016

    Apparent diffusion coefficient-dependent voxelwise computed diffusion-weighted imaging: An approach for improving SNR and reducing T2 shine-through effects.

    • Sergios Gatidis, Holger Schmidt, Petros Martirosian, Konstantin Nikolaou, and Nina F Schwenzer.
    • Department of Radiology, Diagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany.
    • J Magn Reson Imaging. 2016 Apr 1; 43 (4): 824-32.

    PurposeTo introduce and evaluate a method for signal-to-noise ratio (SNR) improvement and T2 shine-through effect reduction in diffusion-weighted magnetic resonance imaging (DWI).Materials And MethodsThe proposed method uses quantitative information given by the voxel apparent diffusion coefficient (ADC) to derive voxelwise-computed DWI (vcDWI). Behavior of signal intensity variations was simulated and correlated with measurements using a dedicated phantom for DWI allowing for independent adjustment of T2 -relaxivity and diffusivity. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were measured and compared to the method of computed DWI (cDWI). Image signal was correlated with ADCs to appreciate the extent of T2 shine-through effects. Additionally, the proposed method was retrospectively applied to whole-body DWI data of 20 patients with metastatic malignancies. vcDWI was compared to cDWI and measured DWI with respect to image quality, lesion detectability, and lesion diffusivity assessment.ResultsTheoretically predicted signal intensity variations showed a high correlation with measured phantom data (r > 0.96). The proposed method yielded lower background signal intensity variation and higher contrast (+144%) and CNR (+358%) for diffusion-restricted phantom compartments than cDWI. Signal intensities of vcDWI showed an increased inverse correlation with phantom ADC values compared to cDWI (r = -0.86 vs. r = -0.73). Application to patient data showed higher image quality (P < 0.001) and lesion detectability (P = 0.011) using vcDWI compared to cDWI, and higher confidence for the correct identification of diffusion-restricted lesions compared to measured DWI (80/80 vs. 60/81; P = 0.013).ConclusionvcDWI is a promising approach for the reduction of T2 shine-through effects and improvement of SNR and CNR in DWI. The clinical significance of these improvements, especially regarding lesion detection, needs to be evaluated in larger prospective clinical studies.© 2015 Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.