-
Rev Chir Orthop Reparatrice Appar Mot · Apr 2001
[Bone reconstruction, leg length discrepancy, and dislocation rate in 52 Wagner revision total hip arthroplasties at 44-month follow-up].
- S Boisgard, P E Moreau, H Tixier, and J P Levai.
- Service de Chirurgie Orthopédique et Traumatologique I, Hôpital G. Montpied, CHU de Clermont-Ferrand, BP 69, 63003 Clermont-Ferrand Cedex 01.
- Rev Chir Orthop Reparatrice Appar Mot. 2001 Apr 1; 87 (2): 147-54.
Purpose Of The StudyThe primary and secondary stability of a revision implant is highly compromised in cases with important loss of bone stock from the proximal femoral after severe femoral loosening. Several methods using implants with or without cement have been proposed for reconstruction after femoral bone loss. The purpose of this study was to analyze mid-term clinical and radiological outcome with the Wagner prosthesis for revision surgery.Material And MethodsFifty-two cases of aseptic femoral loosening were treated with this method in 36 women and 14 men, mean age 70 years (range 32-92 years). None of the patients was lost to follow-up; five who died after 18 months were retained for analysis. Mean follow-up was 44 months (range 18-88 months). The mean preoperative Postel Merle d'Aubigné (PMA) score was 10.5 +/- 0.4. These patients had major bone loss (5 grade II, 24 grade III, 23 grade IV in the SOFCOT classification). The transfemoral access was used in 17 cases and bone grafts in 32. Clinical outcome was assessed with the PMA score and leg length discrepancy was measured. Radiographically, stability was assessed by measuring stem impaction and progression of radiolucent lines.ResultsThe overall functional score was significantly improved from 10.5 +/- 0.4 preoperatively to 14.6 +/- 0.5 (p<0.001). All items on the score improved but pain relief was the most notable. Improvement in the gait score was limited due to persistent limping in 39 patients. Leg length discrepancies were found in 8 patients with 6 shortenings and 2 lengthenings. The clinical situation remained stable after one year. The implant remained stable in 48 patients (92 p. 100) and stem impaction was observed in 4 before 12 months. Two of these cases required a second revision. Metaphyseal reconstruction was observed in 42 patients (81 p. 100), including 24 (46 p. 100) who exhibited homogeneous reconstruction with trabeculation. The reconstruction did not progress further after 18 months postoperatively. Complications included four dislocations and five revision procedures (three for cup loosening, two for femoral pivot instability).DiscussionThe functional outcome was similar to results reported in the literature, including the high frequency of limping that was caused by various factors (valgus prosthesis neck, leg length discrepancy, muscle deficits). Leg length discrepancies resulted from defective positioning or impaction at loading. Standard radiographic series allowed an assessment of stem impaction. Our low rate could be due to delayed weight bearing. La reconstruction of bone loss did not progress after 18 months and was independent of bone grafting, route of access, and the initial degree of loosening. The high frequency of dislocations with this type of implant can be prevented by horizontalization of the acetabulum and use of anti-dislocation inserts at the first intention revision.ConclusionOur results with the Wagner prosthesis are satisfactory both clinically and radiographically. The two drawbacks of this implant (limping and dislocation), partly due to the design of the femoral stem, have led us to study a new implant that preserves good distal anchoring and optimizes the proximal biomechanics of the hip joint.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.