• Radiology · Jul 2006

    Comparative Study

    Focal liver lesions: SPIO-, gadolinium-, and ferucarbotran-enhanced dynamic T1-weighted and delayed T2-weighted MR imaging in rabbits.

    • Jörg Schnorr, Susanne Wagner, Claudia Abramjuk, Randi Drees, Tania Schink, Eyk A Schellenberger, Herbert Pilgrimm, Bernd Hamm, and Matthias Taupitz.
    • Department of Radiology, Charité-Universitätsmedizin Berlin, Schumannstrasse 20/21, 10098 Berlin, Germany. joerg.schnorr@charite.de
    • Radiology. 2006 Jul 1; 240 (1): 90-100.

    PurposeTo compare a superparamagnetic iron oxide (SPIO), VSOP-C184, with a gadopentetate dimeglumine with regard to signal-enhancing effects on T1-weighted dynamic magnetic resonance (MR) images and with another SPIO contrast medium with regard to signal-reducing effects on delayed T2-weighted MR images.Materials And MethodsAll experiments were approved by the responsible Animal Care Committee. Twenty rabbits (five for each contrast agent and dose) implanted with VX-2 carcinoma were imaged at 1.5 T. VSOP-C184 at 0.015 and 0.025 mmol Fe/kg was compared with gadopentetate dimeglumine at 0.15 mmol Gd/kg and ferucarbotran at 0.015 mmol Fe/kg. The imaging protocol comprised a T1-weighted dynamic gradient-echo (GRE) MR before injection and at 6-second intervals for up to 42 seconds after injection and a T2-weighted turbo spin-echo MR before and 5 minutes after injection. Images were evaluated quantitatively, and contrast media were compared by using nonparametric analysis of variance.ResultsAt dynamic T1-weighted GRE MR imaging with 0.015-mmol Fe/kg VSOP-C184, 0.025-mmol Fe/kg VSOP-C184, gadopentetate dimeglumine, and ferucarbotran, the median peak contrast-to-noise ratio (CNR) was 20.7 (25th percentile, 16.3; 75th percentile, 22.6), 24.2 (25th percentile, 19.3; 75th percentile, 28.5), 16.4 (25th percentile, 13.7; 75th percentile, 20.3), and 14.0 (25th percentile, 11.4; 75th percentile, 16.8), respectively. Both doses of VSOP-C184 yielded significantly higher CNR (P < .05) than the other two agents. At T2-weighted turbo spin-echo imaging with 0.015-mmol Fe/kg VSOP-C184, 0.025-mmol Fe/kg VSOP-C184, gadopentetate dimeglumine, and ferucarbotran, the median CNR was 15.0 (25th percentile, 13.4; 75th percentile, 21.3), 15.7 (25th percentile, 14.5; 75th percentile, 19.8), 11.3 (25th percentile, 8.2; 75th percentile, 12.2), and 15.7 (25th percentile, 12.5; 75th percentile, 22.4), respectively. There was no significant difference between VSOP-C184 and ferucarbotran; both had a significantly higher CNR than did gadopentetate dimeglumine.ConclusionVSOP-C184 produces higher liver-to-tumor contrast at dynamic T1-weighted imaging than does gadopentetate dimeglumine; at delayed T2-weighted imaging, the contrast is comparable to that achieved with ferucarbotran.RSNA, 2006

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.